Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Comparison of drug-eluting stents and drug-coated balloon for the treatment of drug-eluting coronary stent restenosis: A randomized RESTORE trial

Full metadata record
DC Field Value Language
dc.contributor.authorWong, Yiu Tung Anthony-
dc.contributor.authorKang, Do-Yoon-
dc.contributor.authorLee, Jin Bae-
dc.contributor.authorRha, Seung-Woon-
dc.contributor.authorHong, Young Joon-
dc.contributor.authorShin, Eun-Seok-
dc.contributor.authorHer, Sung-Ho-
dc.contributor.authorNam, Chang Wook-
dc.contributor.authorChung, Woo-Young-
dc.contributor.authorKim, Moo Hyun-
dc.contributor.authorLee, Cheol Hyun-
dc.contributor.authorLee, Pil Hyung-
dc.contributor.authorAhn, Jung-Min-
dc.contributor.authorKang, Soo-Jin-
dc.contributor.authorLee, Seung-Whan-
dc.contributor.authorKim, Young-Hak-
dc.contributor.authorLee, Cheol Whan-
dc.contributor.authorPark, Seong-Wook-
dc.contributor.authorPark, Duk-Woo-
dc.contributor.authorPark, Seung-Jung-
dc.date.accessioned2021-09-02T14:43:16Z-
dc.date.available2021-09-02T14:43:16Z-
dc.date.created2021-06-16-
dc.date.issued2018-03-
dc.identifier.issn0002-8703-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/77234-
dc.description.abstractBackground This study sought to evaluate the optimal treatment for in-stent restenosis (ISR) of drug-eluting stents (DESs). Methods This is a prospective, multicenter, open-label, randomized study comparing the use of drug-eluting balloon (DEB) versus second-generation everolimus-eluting stent for the treatment of DES ISR. The primary end point was in-segment late loss at 9-month routine angiographic follow-up. Results A total of 172 patients were enrolled, and 74 (43.0%) patients underwent the angiographic follow-up. The primary end point was not different between the 2 treatment groups (DEB group 0.15 +/- 0.49 mm vs DES group 0.19 +/- 0.41 mm, P=.54). The secondary end points of in-segment minimal luminal diameter (MLD) (1.80 +/- 0.69 mm vs 2.09 +/- 0.46 mm, P=.03), in-stent MLD (1.90 +/- 0.71 mm vs 2.29 +/- 0.48 mm, P=.005), in-segment percent diameter stenosis (34% +/- 21% vs 26% +/- 15%, P=.05), and in-stent percent diameter stenosis (33% +/- 21% vs 21% +/- 15%, P=.002) were more favorable in the DES group. The composite of death, myocardial infarction, or target lesion revascularization at 1 year was comparable between the 2 groups (DEB group 7.0% vs DES group 4.7%, P=.51). Conclusions Treatment of DES ISR using DEB or second-generation DES did not differ in terms of late loss at 9-month angiographic follow-up, whereas DES showed better angiographic results regarding minimal MLD and percent diameter stenosis. Both treatment strategies were safe and effective up to 1 year after the procedure.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherMOSBY-ELSEVIER-
dc.subjectBARE-METAL-
dc.subjectCLINICAL-TRIAL-
dc.subjectSIROLIMUS-
dc.subjectIMPLANTATION-
dc.subjectARTERY-
dc.subjectREVASCULARIZATION-
dc.subjectMETAANALYSIS-
dc.subjectANGIOPLASTY-
dc.subjectMULTICENTER-
dc.subjectCATHETER-
dc.titleComparison of drug-eluting stents and drug-coated balloon for the treatment of drug-eluting coronary stent restenosis: A randomized RESTORE trial-
dc.typeArticle-
dc.contributor.affiliatedAuthorRha, Seung-Woon-
dc.identifier.doi10.1016/j.ahj.2017.11.008-
dc.identifier.scopusid2-s2.0-85040018687-
dc.identifier.wosid000425723700005-
dc.identifier.bibliographicCitationAMERICAN HEART JOURNAL, v.197, pp.35 - 42-
dc.relation.isPartOfAMERICAN HEART JOURNAL-
dc.citation.titleAMERICAN HEART JOURNAL-
dc.citation.volume197-
dc.citation.startPage35-
dc.citation.endPage42-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalWebOfScienceCategoryCardiac & Cardiovascular Systems-
dc.subject.keywordPlusBARE-METAL-
dc.subject.keywordPlusCLINICAL-TRIAL-
dc.subject.keywordPlusSIROLIMUS-
dc.subject.keywordPlusIMPLANTATION-
dc.subject.keywordPlusARTERY-
dc.subject.keywordPlusREVASCULARIZATION-
dc.subject.keywordPlusMETAANALYSIS-
dc.subject.keywordPlusANGIOPLASTY-
dc.subject.keywordPlusMULTICENTER-
dc.subject.keywordPlusCATHETER-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Rha, Seung Woon photo

Rha, Seung Woon
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE