Applying Data-driven Imaging Biomarker in Mammography for Breast Cancer Screening: Preliminary Study
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Eun-Kyung | - |
dc.contributor.author | Kim, Hyo-Eun | - |
dc.contributor.author | Han, Kyunghwa | - |
dc.contributor.author | Kang, Bong Joo | - |
dc.contributor.author | Sohn, Yu-Mee | - |
dc.contributor.author | Woo, Ok Hee | - |
dc.contributor.author | Lee, Chan Wha | - |
dc.date.accessioned | 2021-09-02T14:58:43Z | - |
dc.date.available | 2021-09-02T14:58:43Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2018-02-09 | - |
dc.identifier.issn | 2045-2322 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/77365 | - |
dc.description.abstract | We assessed the feasibility of a data-driven imaging biomarker based on weakly supervised learning (DIB; an imaging biomarker derived from large-scale medical image data with deep learning technology) in mammography (DIB-MG). A total of 29,107 digital mammograms from five institutions (4,339 cancer cases and 24,768 normal cases) were included. After matching patients' age, breast density, and equipment, 1,238 and 1,238 cases were chosen as validation and test sets, respectively, and the remainder were used for training. The core algorithm of DIB-MG is a deep convolutional neural network; a deep learning algorithm specialized for images. Each sample (case) is an exam composed of 4-view images (RCC, RMLO, LCC, and LMLO). For each case in a training set, the cancer probability inferred from DIB-MG is compared with the per-case ground-truth label. Then the model parameters in DIB-MG are updated based on the error between the prediction and the ground-truth. At the operating point (threshold) of 0.5, sensitivity was 75.6% and 76.1% when specificity was 90.2% and 88.5%, and AUC was 0.903 and 0.906 for the validation and test sets, respectively. This research showed the potential of DIB-MG as a screening tool for breast cancer. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | NATURE RESEARCH | - |
dc.subject | COMPUTER-AIDED DETECTION | - |
dc.subject | DIGITAL MAMMOGRAPHY | - |
dc.subject | DIAGNOSTIC-ACCURACY | - |
dc.subject | PERFORMANCE | - |
dc.subject | NETWORKS | - |
dc.subject | UPDATE | - |
dc.title | Applying Data-driven Imaging Biomarker in Mammography for Breast Cancer Screening: Preliminary Study | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Woo, Ok Hee | - |
dc.identifier.doi | 10.1038/s41598-018-21215-1 | - |
dc.identifier.scopusid | 2-s2.0-85054190424 | - |
dc.identifier.wosid | 000424634000016 | - |
dc.identifier.bibliographicCitation | SCIENTIFIC REPORTS, v.8 | - |
dc.relation.isPartOf | SCIENTIFIC REPORTS | - |
dc.citation.title | SCIENTIFIC REPORTS | - |
dc.citation.volume | 8 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalWebOfScienceCategory | Multidisciplinary Sciences | - |
dc.subject.keywordPlus | COMPUTER-AIDED DETECTION | - |
dc.subject.keywordPlus | DIGITAL MAMMOGRAPHY | - |
dc.subject.keywordPlus | DIAGNOSTIC-ACCURACY | - |
dc.subject.keywordPlus | PERFORMANCE | - |
dc.subject.keywordPlus | NETWORKS | - |
dc.subject.keywordPlus | UPDATE | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.