Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Macular photostress and visual experience between microscope and intracameral illumination during cataract surgery

Full metadata record
DC Field Value Language
dc.contributor.authorSeo, Hyejin-
dc.contributor.authorDong Heun Nam-
dc.contributor.authorLee, Jong Yeon-
dc.contributor.authorPark, Su Jin-
dc.contributor.authorKim, Yu Jeong-
dc.contributor.authorKim, Seong-Woo-
dc.contributor.authorChung, Tae-Young-
dc.contributor.authorInoue, Makoto-
dc.contributor.authorKim, Terry-
dc.date.accessioned2021-09-02T15:46:19Z-
dc.date.available2021-09-02T15:46:19Z-
dc.date.created2021-06-16-
dc.date.issued2018-02-
dc.identifier.issn0886-3350-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/77794-
dc.description.abstractPurpose: To evaluate macular photostress and visual experience between coaxial microscope illumination versus oblique intracameral illumination during cataract surgery. Setting: Gachon University Gil Hospital, Incheon, South Korea. Design: Prospective case series. Methods: Consecutive patients who had cataract surgery using microscope illumination and intracameral illumination were included. The patients were asked to complete a questionnaire (seeing strong lights, feeling photophobia, feeling startled (fright) when seeing lights, seeing any colors, seeing any instruments or surgical procedures, and estimating intraoperative visual function) designed to describe their cataract surgery experience. The images projected on the retina of the model eye (rear view) with artificial opaque fragments in the anterior chamber during simulating cataract surgery were compared between the 2 illumination types. Results: Sixty patients completed the questionnaire. Scores for strong lights, photophobia, fright, and color perception were significantly higher with microscope illumination than with intracameral illumination (all P < .001). More patients preferred the intracameral illumination (45 [75.0%]) to the microscope illumination (13 [21.7%]). In the rear-view images created in a model eye, only the bright microscope light in the center was seen without any lens image in the microscope illumination. However, in the intracameral illumination, the less bright light from the light pipe in the periphery and the lens fragments were seen more clearly. Conclusions: In a view of the patients' visual experience, oblique intracameral illumination caused less subjective photostress and was preferred over coaxial microscope illumination. Objective findings from the model-eye experiment correlated to the result of visual experience. (c) 2018 ASCRS and ESCRS-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE INC-
dc.subjectOPERATING MICROSCOPE-
dc.subjectPHACOEMULSIFICATION-
dc.subjectEYES-
dc.subjectCAPSULE-
dc.subjectPATIENT-
dc.subjectSYSTEM-
dc.subject1ST-
dc.titleMacular photostress and visual experience between microscope and intracameral illumination during cataract surgery-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Seong-Woo-
dc.identifier.doi10.1016/j.jcrs.2017.11.016-
dc.identifier.scopusid2-s2.0-85044438861-
dc.identifier.wosid000429500800013-
dc.identifier.bibliographicCitationJOURNAL OF CATARACT AND REFRACTIVE SURGERY, v.44, no.2, pp.190 - 197-
dc.relation.isPartOfJOURNAL OF CATARACT AND REFRACTIVE SURGERY-
dc.citation.titleJOURNAL OF CATARACT AND REFRACTIVE SURGERY-
dc.citation.volume44-
dc.citation.number2-
dc.citation.startPage190-
dc.citation.endPage197-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaOphthalmology-
dc.relation.journalResearchAreaSurgery-
dc.relation.journalWebOfScienceCategoryOphthalmology-
dc.relation.journalWebOfScienceCategorySurgery-
dc.subject.keywordPlusOPERATING MICROSCOPE-
dc.subject.keywordPlusPHACOEMULSIFICATION-
dc.subject.keywordPlusEYES-
dc.subject.keywordPlusCAPSULE-
dc.subject.keywordPlusPATIENT-
dc.subject.keywordPlusSYSTEM-
dc.subject.keywordPlus1ST-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE