Use of the Posterior/Anterior Corneal Curvature Radii Ratio to Improve the Accuracy of Intraocular Lens Power Calculation: Eom's Adjustment Method
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Mingue | - |
dc.contributor.author | Eom, Youngsub | - |
dc.contributor.author | Lee, Hwa | - |
dc.contributor.author | Suh, Young-Woo | - |
dc.contributor.author | Song, Jong Suk | - |
dc.contributor.author | Kim, Hyo Myung | - |
dc.date.accessioned | 2021-09-02T15:59:17Z | - |
dc.date.available | 2021-09-02T15:59:17Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2018-02 | - |
dc.identifier.issn | 0146-0404 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/77902 | - |
dc.description.abstract | PURPOSE. To evaluate the accuracy of IOL power calculation using adjusted corneal power according to the posterior/anterior corneal curvature radii ratio. METHODS. Nine hundred twenty-eight eyes from 928 reference subjects and 158 eyes from 158 cataract patients who underwent phacoemulsification surgery were enrolled. Adjusted corneal power of cataract patients was calculated using the fictitious refractive index that was obtained from the geometric mean posterior/anterior corneal curvature radii ratio of reference subjects and adjusted anterior and predicted posterior corneal curvature radii from conventional keratometry (K) using the posterior/anterior corneal curvature radii ratio. The median absolute error (MedAE) based on the adjusted corneal power was compared with that based on conventional K in the Haigis and SRK/T formulae. RESULTS. The geometric mean posterior/anterior corneal curvature radii ratio was 0.808, and the fictitious refractive index of the cornea for a single Scheimpflug camera was 1.3275. The mean difference between adjusted corneal power and conventional K was 0.05 diopter (D). The MedAE based on adjusted corneal power (0.31 D in the Haigis formula and 0.32 D in the SRK/T formula) was significantly smaller than that based on conventional K (0.41 D and 0.40 D, respectively; P < 0.001 and P < 0.001, respectively). The percentage of eyes with refractive prediction error within +/- 0.50 D calculated using adjusted corneal power (74.7%) was significantly greater than that obtained using conventional K (62.7%) in the Haigis formula (P = 0.029). CONCLUSIONS. IOL power calculation using adjusted corneal power according to the posterior/anterior corneal curvature radii ratio provided more accurate refractive outcomes than calculation using conventional K. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ASSOC RESEARCH VISION OPHTHALMOLOGY INC | - |
dc.subject | ROTATING SCHEIMPFLUG CAMERA | - |
dc.subject | REFRACTIVE SURGERY | - |
dc.subject | HAIGIS FORMULAS | - |
dc.subject | SHORT EYES | - |
dc.subject | IOL POWER | - |
dc.subject | POSITION | - |
dc.subject | ANTERIOR | - |
dc.subject | ERROR | - |
dc.subject | REPEATABILITY | - |
dc.subject | ASTIGMATISM | - |
dc.title | Use of the Posterior/Anterior Corneal Curvature Radii Ratio to Improve the Accuracy of Intraocular Lens Power Calculation: Eom's Adjustment Method | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Eom, Youngsub | - |
dc.contributor.affiliatedAuthor | Lee, Hwa | - |
dc.contributor.affiliatedAuthor | Suh, Young-Woo | - |
dc.contributor.affiliatedAuthor | Song, Jong Suk | - |
dc.contributor.affiliatedAuthor | Kim, Hyo Myung | - |
dc.identifier.doi | 10.1167/iovs.17-22405 | - |
dc.identifier.scopusid | 2-s2.0-85042272248 | - |
dc.identifier.wosid | 000426346300045 | - |
dc.identifier.bibliographicCitation | INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, v.59, no.2, pp.1016 - 1024 | - |
dc.relation.isPartOf | INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE | - |
dc.citation.title | INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE | - |
dc.citation.volume | 59 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 1016 | - |
dc.citation.endPage | 1024 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Ophthalmology | - |
dc.relation.journalWebOfScienceCategory | Ophthalmology | - |
dc.subject.keywordPlus | ROTATING SCHEIMPFLUG CAMERA | - |
dc.subject.keywordPlus | REFRACTIVE SURGERY | - |
dc.subject.keywordPlus | HAIGIS FORMULAS | - |
dc.subject.keywordPlus | SHORT EYES | - |
dc.subject.keywordPlus | IOL POWER | - |
dc.subject.keywordPlus | POSITION | - |
dc.subject.keywordPlus | ANTERIOR | - |
dc.subject.keywordPlus | ERROR | - |
dc.subject.keywordPlus | REPEATABILITY | - |
dc.subject.keywordPlus | ASTIGMATISM | - |
dc.subject.keywordAuthor | intraocular lens | - |
dc.subject.keywordAuthor | calculation | - |
dc.subject.keywordAuthor | corneal power | - |
dc.subject.keywordAuthor | posterior corneal radius | - |
dc.subject.keywordAuthor | cataract | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.