Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Transradial access for cerebrovascular angiography: Evaluation of palmar collateral circulation with hand angiography and its correlation with Allen test

Authors
Kwon, Woo-KeunYoon, WonkiKwon, Taek-HyunKim, Jong HyunJung, Heung-SubAhn, JaegeunHuh, HanyongJi, Choel
Issue Date
1월-2018
Publisher
ELSEVIER SCIENCE BV
Keywords
Allen test; Transradial cerebral angiography; Palmar circulation; Doppler ultrasonography; Plethysmography
Citation
CLINICAL NEUROLOGY AND NEUROSURGERY, v.164, pp.14 - 18
Indexed
SCIE
SCOPUS
Journal Title
CLINICAL NEUROLOGY AND NEUROSURGERY
Volume
164
Start Page
14
End Page
18
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/78498
DOI
10.1016/j.clineuro.2017.10.035
ISSN
0303-8467
Abstract
Objectives: Transradial cerebral angiography (TRCA) has been introduced as an alternative technique for the transfemoral access, and its use is becoming more common in the field. In this study, we retrospectively analyzed a group of patients who received TRCA, and investigated peri-procedural measurements indicating actual hand circulation, and studied their correlation with the Allen test. Patients and methods: A retrospective review of 168 patients whom underwent TRCA between 2015 July and 2016 July, were included in this study. Pre procedural Allen test and Doppler ultrasonography for the radial artery (RA) and ulnar artery (UA) were done. Plethysmography tests as well as pulse oximetry monitoring were done before and during the procedure and intra-procedural angiography of the forearm and hand was done for assessment of palmar circulation. Results: Pre-procedural UA diameters revealed statistically significant correlation with manual Allen test results (P < 0.001, r = -0.381). The DUS RA diameters, however, did not correlate with any other pre-procedural measurements. The mean contrast filling time on forearm angiography was 3.33 +/- 1.97 s, and it showed statistically significant correlation with the capillary filling time of Allen tests (P < 0.001, r = -0.389). Conclusion: Manual Allen test results correlated with angiographic capillary filling of the distal hand circulation and pre-procedural UA diameters. Our results suggest that Allen test sufficiently represent the collateral circulation status prior to TRCA.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jong Hyun photo

Kim, Jong Hyun
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE