하악 총의치 전용의 유리섬유 보강재 적용에 따른 적합도 비교 분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 김웅철 | - |
dc.contributor.author | 김동연 | - |
dc.contributor.author | 박진영 | - |
dc.contributor.author | 배소연 | - |
dc.contributor.author | 강후원 | - |
dc.contributor.author | 김지환 | - |
dc.date.accessioned | 2021-09-02T17:26:53Z | - |
dc.date.available | 2021-09-02T17:26:53Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2018 | - |
dc.identifier.issn | 1229-3954 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/78656 | - |
dc.description.abstract | Purpose: The purpose of this study is to evaluate the fitness of lower jaw compete denture with glass fiber. Methods: Lower jaw edentulous model was selected as the master model. Ten study models were produced using Type Ⅳ stone(n=10). Lower jaw trial dentures were produced by the wax denture base and artificial teeth. Conventional complete denture (CD) group was fabricated by excluding glass fiber reinforcement (n=5). Glass fiber complete denture (GD) group was fabricated with glass fiber reinforcement (n=5). The lower jaw trial complete denture was invested using a plaster. PMMA resin was injected and curing was performed. The CD and GD groups measured the fit using silicone replica technology. The measured data was verified by t-test. Results: The anterior area of the CD group showed the smallest value. There was a statistically significant difference in the anterior area of the CD group and the GD group (p<0.05), but there was no statistically significant difference in the posterior area (p>0.05). Conclusion : Complete denture with glass fiber showed low fitness and further study is needed to apply it clinically. | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 대한치과기공학회 | - |
dc.title | 하악 총의치 전용의 유리섬유 보강재 적용에 따른 적합도 비교 분석 | - |
dc.title.alternative | Evaluation of fitness according to application of glass fiber reinforcement for lower jaw complete denture | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 김지환 | - |
dc.identifier.doi | 10.14347/kadt.2018.40.4.201 | - |
dc.identifier.bibliographicCitation | 대한치과기공학회지, v.40, no.4, pp.201 - 207 | - |
dc.relation.isPartOf | 대한치과기공학회지 | - |
dc.citation.title | 대한치과기공학회지 | - |
dc.citation.volume | 40 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 201 | - |
dc.citation.endPage | 207 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002416273 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Edentulous | - |
dc.subject.keywordAuthor | Complete denture | - |
dc.subject.keywordAuthor | Glass fiber | - |
dc.subject.keywordAuthor | PMMA | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.