dc.description.abstract | Purpose: The aim of this study was to evaluate accuracy of three type complete mandibular denture of before and after polymerization. Methods: Mandibular edentulous model was selected as the master model. 15 study models were made by Type Ⅳ stone. Wax complete mandibular dentures were produced by the denture base and artificial teeth. Before and after curing, STL files were obtained using a blue scanner. By superimposing the digitized complete mandibular denture data(after curing) with the CAD-reference(before curing) three-dimensionally, visual fit-discrepancies were drawn by calculating the root mean square (RMS) and visualized on a color-difference map. Each calculated RMS-value was statistically analyzed by 1-way analysis of variance(ANOVA) (α = .05). Results: Mean(SD) RMS-values was OM group 88.98(6.10)㎛, BM group 82.35(13.46)㎛, BDM group 77.83(9.46)㎛. The results of the 1-way ANOVA showed no statistically significant differences in the RMS values of the Three groups for the material (P > .241). Conclusion : Deformation of artificial teeth position was observed in all groups after resin polymerization. But the values, all group were within the clinically acceptable range. The values of BDM group showed the least deformation than the other two groups. | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 대한치과기공학회 | - |
dc.title | 세 가지 방식으로 제작한 하악 총의치의 중합 전후에 따른 인공치아 위치 3차원 분석 | - |
dc.title.alternative | Three-dimensional analysis of artificial teeth position according to three type complete mandibular denture before and after polymerization | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 김지환 | - |
dc.identifier.doi | 10.14347/kadt.2018.40.4.217 | - |
dc.identifier.bibliographicCitation | 대한치과기공학회지, v.40, no.4, pp.217 - 224 | - |
dc.relation.isPartOf | 대한치과기공학회지 | - |
dc.citation.title | 대한치과기공학회지 | - |
dc.citation.volume | 40 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 217 | - |
dc.citation.endPage | 224 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002416364 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Complete mandibular denture | - |
dc.subject.keywordAuthor | Polymerization | - |
dc.subject.keywordAuthor | Three-dimensional analysis | - |
dc.subject.keywordAuthor | Bar-type glass fiber mesh | - |
dc.subject.keywordAuthor | Shrinkage | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.