Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 최영 | - |
dc.contributor.author | 엄영섭 | - |
dc.contributor.author | 송종석 | - |
dc.contributor.author | 김효명 | - |
dc.date.accessioned | 2021-09-02T20:04:23Z | - |
dc.date.available | 2021-09-02T20:04:23Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2018 | - |
dc.identifier.issn | 1011-8942 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/80255 | - |
dc.description.abstract | Purpose: To compare the effect of posterior corneal astigmatism on the estimation of total corneal astigmatism using anterior corneal measurements (simulated keratometry [K]) between eyes with keratoconus and healthy eyes. Methods: Thirty-three eyes of 33 patients with keratoconus of grade I or II and 33 eyes of 33 age- and sexmatched healthy control subjects were enrolled. Anterior, posterior, and total corneal cylinder powers and flat meridians measured by a single Scheimpflug camera were analyzed. The difference in corneal astigmatism between the simulated K and total cornea was evaluated. Results: The mean anterior, posterior, and total corneal cylinder powers of the keratoconus group (4.37 ± 1.73, 0.95 ± 0.39, and 4.36 ± 1.74 cylinder diopters [CD], respectively) were significantly greater than those of the control group (1.10 ± 0.68, 0.39 ± 0.18, and 0.97 ± 0.63 CD, respectively). The cylinder power difference between the simulated K and total cornea was positively correlated with the posterior corneal cylinder power and negatively correlated with the absolute flat meridian difference between the simulated K and total cornea in both groups. The mean magnitude of the vector difference between the astigmatism of the simulated K and total cornea of the keratoconus group (0.67 ± 0.67 CD) was significantly larger than that of the control group (0.28 ± 0.12 CD). Conclusions: Eyes with keratoconus had greater estimation errors of total corneal astigmatism based on anterior corneal measurement than did healthy eyes. Posterior corneal surface measurement should be more emphasized to determine the total corneal astigmatism in eyes with keratoconus. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | 대한안과학회 | - |
dc.title | Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes | - |
dc.title.alternative | Comparison of Anterior, Posterior, and Total Corneal Astigmatism Measured Using a Single Scheimpflug Camera in Healthy and Keratoconus Eyes | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 엄영섭 | - |
dc.identifier.doi | 10.3341/kjo.2017.0075 | - |
dc.identifier.bibliographicCitation | Korean Journal of Ophthalmology, v.32, no.3, pp.163 - 171 | - |
dc.relation.isPartOf | Korean Journal of Ophthalmology | - |
dc.citation.title | Korean Journal of Ophthalmology | - |
dc.citation.volume | 32 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 163 | - |
dc.citation.endPage | 171 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002352526 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Astigmatism | - |
dc.subject.keywordAuthor | Cornea | - |
dc.subject.keywordAuthor | Keratoconus | - |
dc.subject.keywordAuthor | Posterior corneal astigmatism | - |
dc.subject.keywordAuthor | Total corneal astigmatism | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.