Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Performance Evaluation of Compton Micro-PET for Detector Modalities: A Monte Carlo Study

Full metadata record
DC Field Value Language
dc.contributor.authorYoon, Changyeon-
dc.contributor.authorLee, Wonho-
dc.date.accessioned2021-09-02T21:16:38Z-
dc.date.available2021-09-02T21:16:38Z-
dc.date.created2021-06-16-
dc.date.issued2018-
dc.identifier.issn0029-5450-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/80959-
dc.description.abstractPerformance of Compton positron emission tomography (PET) is studied in this paper using qualitative and quantitative methods. Lutetium yttrium oxyorthosilicate (LYSO), lutetium-gadolinium oxyorthosilicate (LGSO), and CdZnTe (CZT) materials are used for Compton PET. LYSO is widely used for conventional PET, and LGSO is a prospective scintillator material for PET detectors. CZT is one of the semiconductor materials that have high energy and position resolution. For conventional PET, only the photoelectric effect is considered a valid interaction for image reconstruction. However, Compton scattering tracing technology is applied for our Compton PET to additionally use Compton scattering events for image reconstruction. It is relatively difficult to use multiple layers for PET made of scintillators, as electronic circuits must be attached to each layer. For this reason, conventional PET generally uses only one layer for each detector module and limits the spatial resolution in the depth direction. In contrast, it is possible for a CZT detector to measure a depth of interest based on the cathode-to-anode signal ratio or electron drift time with relatively simple electronic circuits. Furthermore, CZT materials have high spatial and energy resolutions. Therefore, the position and energy information of the radiation interactions in the detector module can be precisely calculated to determine the interaction sequence, and hence, the information from the Compton scattering can be used for image reconstruction in PET. For this reason, the reconstructed image of CZT PET can show better quality than those of scintillator PETs. The detection efficiency and quality of the reconstructed image are significantly increased by including the Compton scattering effect as a valid interaction process for image reconstruction because Compton scattering has twice the interaction probability of the photoelectric effect at 511 keV. In this paper, the effectiveness of including Compton scattering events for PET reconstruction was evaluated for scintillators and CZT semiconductor detectors. The maximum likelihood expectation and maximisation reconstruction method was applied for conventional and Compton PET reconstruction, and the qualities of the reconstructed images were evaluated.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherTAYLOR & FRANCIS INC-
dc.subjectSCINTILLATION PROPERTIES-
dc.subjectEM RECONSTRUCTION-
dc.subjectIMAGE QUALITY-
dc.subjectRESOLUTION-
dc.subjectSCANNER-
dc.subjectALGORITHM-
dc.subjectCAMERA-
dc.subjectLIKELIHOOD-
dc.subjectCRYSTALS-
dc.subjectGROWTH-
dc.titlePerformance Evaluation of Compton Micro-PET for Detector Modalities: A Monte Carlo Study-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Wonho-
dc.identifier.doi10.1080/00295450.2018.1493318-
dc.identifier.scopusid2-s2.0-85052098176-
dc.identifier.wosid000450403500010-
dc.identifier.bibliographicCitationNUCLEAR TECHNOLOGY, v.204, no.3, pp.386 - 395-
dc.relation.isPartOfNUCLEAR TECHNOLOGY-
dc.citation.titleNUCLEAR TECHNOLOGY-
dc.citation.volume204-
dc.citation.number3-
dc.citation.startPage386-
dc.citation.endPage395-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.subject.keywordPlusSCINTILLATION PROPERTIES-
dc.subject.keywordPlusEM RECONSTRUCTION-
dc.subject.keywordPlusIMAGE QUALITY-
dc.subject.keywordPlusRESOLUTION-
dc.subject.keywordPlusSCANNER-
dc.subject.keywordPlusALGORITHM-
dc.subject.keywordPlusCAMERA-
dc.subject.keywordPlusLIKELIHOOD-
dc.subject.keywordPlusCRYSTALS-
dc.subject.keywordPlusGROWTH-
dc.subject.keywordAuthorMonte Carlo study-
dc.subject.keywordAuthorCompton PET-
dc.subject.keywordAuthorsemiconductor PET-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Won ho photo

Lee, Won ho
보건과학대학 (보건환경융합과학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE