Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Robust Extrinsic Calibration Method f or Non-Contact Gaze Tracking in the 3-D Space

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Mun-Cheon-
dc.contributor.authorYoo, Cheol-Hwan-
dc.contributor.authorUhm, Kwang-Hyun-
dc.contributor.authorLee, Dae-Hong-
dc.contributor.authorKo, Sung-Jea-
dc.date.accessioned2021-09-02T21:17:26Z-
dc.date.available2021-09-02T21:17:26Z-
dc.date.created2021-06-16-
dc.date.issued2018-
dc.identifier.issn2169-3536-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/80968-
dc.description.abstractIn general, 3-D gaze tracking methods employ both a frontal-viewing camera and an eye-capturing camera facing the opposite direction to precisely estimate the point-of-regard (POR) in the 3-D space. The extrinsic calibration of these two cameras for accurate 3-D gaze tracking is a challenging task. This paper presents a robust extrinsic calibration method for non-contact gaze tracking in the 3-D space. Even in a noisy environment, the extrinsic calibration parameters are precisely estimated by minimizing the proposed cost function consisting of both the angular and Euclidean errors. Furthermore, using the estimated parameters, the 3-D POR is exactly determined based on the two-view geometry. Compared with the conventional methods, the proposed method provides superior results in experiments considering various factors such as the noise level, head movement, and camera configuration. In real experiments, we achieved an average Euclidean error of 12.6 cm and the average angular error of 0.98 degrees when estimating the 3-D coordinates of PORs that were 4-8 m away from the user.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC-
dc.subjectSYSTEMS-
dc.titleA Robust Extrinsic Calibration Method f or Non-Contact Gaze Tracking in the 3-D Space-
dc.typeArticle-
dc.contributor.affiliatedAuthorKo, Sung-Jea-
dc.identifier.doi10.1109/ACCESS.2018.2867235-
dc.identifier.scopusid2-s2.0-85052705706-
dc.identifier.wosid000445412800001-
dc.identifier.bibliographicCitationIEEE ACCESS, v.6, pp.48840 - 48849-
dc.relation.isPartOfIEEE ACCESS-
dc.citation.titleIEEE ACCESS-
dc.citation.volume6-
dc.citation.startPage48840-
dc.citation.endPage48849-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaComputer Science-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaTelecommunications-
dc.relation.journalWebOfScienceCategoryComputer Science, Information Systems-
dc.relation.journalWebOfScienceCategoryEngineering, Electrical & Electronic-
dc.relation.journalWebOfScienceCategoryTelecommunications-
dc.subject.keywordPlusSYSTEMS-
dc.subject.keywordAuthorCalibration-
dc.subject.keywordAuthorgaze tracking-
dc.subject.keywordAuthorcomputer vision-
dc.subject.keywordAuthorhuman computer interaction-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Electrical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE