Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Improvement of Droplet Speed and Stability in Electrowetting on Dielectric Devices by Surface Polishing

Full metadata record
DC Field Value Language
dc.contributor.authorShirinkami, Hamidreza-
dc.contributor.authorKim, Jiman-
dc.contributor.authorLee, Choonghee-
dc.contributor.authorKim, Hee Chan-
dc.contributor.authorChun, Honggu-
dc.date.accessioned2021-09-02T22:19:32Z-
dc.date.available2021-09-02T22:19:32Z-
dc.date.created2021-06-16-
dc.date.issued2017-12-
dc.identifier.issn1976-0280-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/81325-
dc.description.abstractThis paper reports on a technique that significantly improves the performance of open-plate electrowetting on dielectric (EWOD) devices by using chemical mechanical polishing (CMP) to achieve surface planarization. In EWOD devices, trenches are inevitably generated during fabrication, and these can have a considerable effect on droplet manipulation. Such artefacts lead to a local intensification in the electric field that not only hinders the droplet movement due to a partially increased adhesion force, but also limits the maximum applicable potential by increasing the likelihood of a dielectric breakdown. We conducted theoretical and experimental studies on the effect of trenches on the performance of both unpolished and polished EWOD devices. Various combinations of the droplet volume and electrode size were tested, and our proposed technique resulted in a notable improvement for all cases. For instance, when operating at 100 V, a 3.5 mu L droplet could be translated at 70 mm/s on the polished EWOD device, which is twice as fast as that for its unpolished counterpart at the same voltage. Also, the maximum applicable potential resulting in a dielectric breakdown of the polished EWOD device was measured to be 27% higher than that of a conventional device.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN BIOCHIP SOCIETY-KBCS-
dc.subjectON-A-CHIP-
dc.subjectDIGITAL MICROFLUIDICS-
dc.subjectCONTACT-ANGLE-
dc.titleImprovement of Droplet Speed and Stability in Electrowetting on Dielectric Devices by Surface Polishing-
dc.typeArticle-
dc.contributor.affiliatedAuthorChun, Honggu-
dc.identifier.doi10.1007/s13206-017-1408-4-
dc.identifier.scopusid2-s2.0-85040097199-
dc.identifier.wosid000419485600008-
dc.identifier.bibliographicCitationBIOCHIP JOURNAL, v.11, no.4, pp.316 - 321-
dc.relation.isPartOfBIOCHIP JOURNAL-
dc.citation.titleBIOCHIP JOURNAL-
dc.citation.volume11-
dc.citation.number4-
dc.citation.startPage316-
dc.citation.endPage321-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002291638-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaBiochemistry & Molecular Biology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryBiochemical Research Methods-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.subject.keywordPlusON-A-CHIP-
dc.subject.keywordPlusDIGITAL MICROFLUIDICS-
dc.subject.keywordPlusCONTACT-ANGLE-
dc.subject.keywordAuthorDigital microfluidics-
dc.subject.keywordAuthorElectrowetting on dielectric (EWOD)-
dc.subject.keywordAuthorDroplet microfluidics-
dc.subject.keywordAuthorDielectric breakdown-
dc.subject.keywordAuthorChemical mechanical polishing (CMP)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Bioengineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHUN, Hong gu photo

CHUN, Hong gu
바이오의공학과
Read more

Altmetrics

Total Views & Downloads

BROWSE