Evaluation of mandibular lingula and foramen location using 3-dimensional mandible models reconstructed by cone-beam computed tomography
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Zhou, Cong | - |
dc.contributor.author | Jeon, Tae-Hyun | - |
dc.contributor.author | Jun, Sang-Ho | - |
dc.contributor.author | Kwon, Jong-Jin | - |
dc.date.accessioned | 2021-09-02T22:20:46Z | - |
dc.date.available | 2021-09-02T22:20:46Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2017-12 | - |
dc.identifier.issn | 2288-8101 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/81336 | - |
dc.description.abstract | Background: The positions of the mandibular lingula and foramen have been set as indexes for inferior alveolar nerve (IAN) block and ramus osteotomies in orthognathic surgery. This study aimed to evaluate the anatomical structures of mandibular ramus, especially the mandibular lingula and foramen, by analyzing the cone-beam computed tomography (CBCT) data of young adults. Methods: We evaluated 121 sides of hemi-mandibular CBCT model of 106 patients (51 male and 55 female patients; 18 to 36 years old). All the measurements were performed using the 2- and 3-dimensional rulers of OnDemand3D (R) software. Results: Statistical analysis of the data revealed that there was no significant difference in the mandibular angle between the genders. The mandibular lingula was found to be located at the center of ramus in males, but a little posterior in relation to the center in females. The mandibular lingula was rarely located below the occlusal plane; however, the position of the mandibular foramen was more variable (84.3% below, 12.4% above, and 3.3% at the level of the occlusal plane). Conclusions: The results of this study provide a valuable guideline for IAN block anesthesia and orthognathic surgery. CBCT can be considered effective and accurate in evaluating the fine structures of the mandible. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | SPRINGEROPEN | - |
dc.title | Evaluation of mandibular lingula and foramen location using 3-dimensional mandible models reconstructed by cone-beam computed tomography | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Jun, Sang-Ho | - |
dc.identifier.doi | 10.1186/s40902-017-0128-y | - |
dc.identifier.wosid | 000485117300030 | - |
dc.identifier.bibliographicCitation | MAXILLOFACIAL PLASTIC AND RECONSTRUCTIVE SURGERY, v.39, no.1 | - |
dc.relation.isPartOf | MAXILLOFACIAL PLASTIC AND RECONSTRUCTIVE SURGERY | - |
dc.citation.title | MAXILLOFACIAL PLASTIC AND RECONSTRUCTIVE SURGERY | - |
dc.citation.volume | 39 | - |
dc.citation.number | 1 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002282594 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
dc.subject.keywordAuthor | 3D Anatomy | - |
dc.subject.keywordAuthor | Mandibular ramus | - |
dc.subject.keywordAuthor | Lingula | - |
dc.subject.keywordAuthor | Foramen | - |
dc.subject.keywordAuthor | Cone-beam CT | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.