Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Interfacial shear behavior of a high-strength pile to sleeve grouted connection

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Jeong-Hwa-
dc.contributor.authorWon, Deok-Hee-
dc.contributor.authorJeong, Youn-Ju-
dc.contributor.authorIim, Seong-Hwan-
dc.contributor.authorKang, Young-Jong-
dc.date.accessioned2021-09-02T23:02:57Z-
dc.date.available2021-09-02T23:02:57Z-
dc.date.created2021-06-19-
dc.date.issued2017-11-15-
dc.identifier.issn0141-0296-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/81540-
dc.description.abstractA grouted connection is a type of structural composite connection member produced from two different sized steel tubes and a grout annulus between them. The grouted connection has been widely used in offshore oil and gas platforms and wind turbine structures by simply grouting between the pile and sleeves. In general, the axial compression strength of the connection is known to be affected by the grout strength, shear-key spacing and radial stiffness parameters of the composite section. In this study, concentric and eccentric loading tests were performed to investigate the interfacial shear behavior of the high-strength grouted connections according to the shear-key spacings. The interface shear behaviors, focusing on the strength, failure mode, and strain of the grout and steel tubes, were evaluated by tests and finite element (FE) analysis. The test results showed that the primary strength of the connection was mainly affected by the grout strength, whereas the ultimate strength was affected by the yield strength of the sleeves and the friction coefficient between the steel tubes and grout. It was also concluded that the test results on the high-strength grouted connections were similar to those of previous studies on normal-strength grouted connections, and the eccentric loading did not reduce the axial capacity of the connection. Although the ultimate failure modes of the connections could not be considered in the current design equations, they may contribute to the safe design of high-strength grouted connections. (C) 2017 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCI LTD-
dc.titleInterfacial shear behavior of a high-strength pile to sleeve grouted connection-
dc.typeArticle-
dc.contributor.affiliatedAuthorKang, Young-Jong-
dc.identifier.doi10.1016/j.engstruct.2017.08.035-
dc.identifier.scopusid2-s2.0-85029516468-
dc.identifier.wosid000412960600051-
dc.identifier.bibliographicCitationENGINEERING STRUCTURES, v.151, pp.704 - 723-
dc.relation.isPartOfENGINEERING STRUCTURES-
dc.citation.titleENGINEERING STRUCTURES-
dc.citation.volume151-
dc.citation.startPage704-
dc.citation.endPage723-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryEngineering, Civil-
dc.subject.keywordAuthorHigh-strength grout-
dc.subject.keywordAuthorGrouted connection-
dc.subject.keywordAuthorOffshore wind turbine-
dc.subject.keywordAuthorShear-key spacing-
dc.subject.keywordAuthorEccentric loading-
dc.subject.keywordAuthorComposite structure-
dc.subject.keywordAuthorOffshore structure-
dc.subject.keywordAuthorInterfacial shear behavior-
dc.subject.keywordAuthorExperimental study-
dc.subject.keywordAuthorFinite element analysis-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Young Jong photo

Kang, Young Jong
공과대학 (건축사회환경공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE