Characteristics of fiber-optic radiation sensor for passive scattering proton beams

Full metadata record
DC Field Value Language
dc.contributor.authorSon, J.-
dc.contributor.authorKim, M.-
dc.contributor.authorJeong, J.-
dc.contributor.authorLim, Y.-
dc.contributor.authorLee, S. B.-
dc.contributor.authorShin, D.-
dc.contributor.authorYoon, M.-
dc.date.accessioned2021-09-02T23:18:02Z-
dc.date.available2021-09-02T23:18:02Z-
dc.date.created2021-06-19-
dc.date.issued2017-11-
dc.identifier.issn1748-0221-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/81647-
dc.description.abstractThe aims of this study were to investigate the characteristics of a fiber-optic radiation sensor (FORS) that detects the fluorescence light produced by proton beam and to verify its effectiveness in proton therapy quality assurance (QA). Various characteristics of the FORS were investigated, such as the linearity of its relationships to the sensitive length of fiber for the proton beams of intermediate ranges (165.46 and 178.37 MeV) and to the measured dose, as well as its dose rate dependence. In addition, patient specific precription dose QA was conducted for five patients actually undergoing proton therapy and the results were compared with the doses measured using an ion chamber. The results show that the signal of the FORS is linearly related to the sensitive length of fiber and to the irradiated dose in the range from 1 to 500 cGy. The QA results obtained using the FORS system showed good agreement with the corresponding ion chamber results, with an average difference of 0.40% and a standard deviation of 0.35%. The FORS was dose-rate independent for proton currents up to 5 Gy/min. The profiles of various proton beams obtained using an array of FORS, which were measured as an application of the developed dosimetric system, closely agreed with the profiles acquired using EBT3 film. In summary, the experimental results of FORS demonstrated its effectiveness for use in various proton therapy QA tests.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIOP PUBLISHING LTD-
dc.subjectPLASTIC SCINTILLATION DETECTORS-
dc.subjectCERENKOV RADIATION-
dc.subjectDOSIMETRY-
dc.subjectTHERAPY-
dc.subjectFIBERS-
dc.subjectARRAY-
dc.titleCharacteristics of fiber-optic radiation sensor for passive scattering proton beams-
dc.typeArticle-
dc.contributor.affiliatedAuthorYoon, M.-
dc.identifier.doi10.1088/1748-0221/12/11/P11015-
dc.identifier.scopusid2-s2.0-85038599942-
dc.identifier.wosid000415822400008-
dc.identifier.bibliographicCitationJOURNAL OF INSTRUMENTATION, v.12-
dc.relation.isPartOfJOURNAL OF INSTRUMENTATION-
dc.citation.titleJOURNAL OF INSTRUMENTATION-
dc.citation.volume12-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.subject.keywordPlusPLASTIC SCINTILLATION DETECTORS-
dc.subject.keywordPlusCERENKOV RADIATION-
dc.subject.keywordPlusDOSIMETRY-
dc.subject.keywordPlusTHERAPY-
dc.subject.keywordPlusFIBERS-
dc.subject.keywordPlusARRAY-
dc.subject.keywordAuthorDosimetry concepts and apparatus-
dc.subject.keywordAuthorPhoton detectors for UV, visible and IR photons (vacuum) (photomultipliers, HPDs, others)-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Myong geun photo

Yoon, Myong geun
보건과학대학 (바이오의공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE