Advanced Reactive Power Reserve Management Scheme to Enhance LVRT Capability
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Hwanik | - |
dc.contributor.author | Bae, Moonsung | - |
dc.contributor.author | Lee, Byongjun | - |
dc.date.accessioned | 2021-09-03T00:22:37Z | - |
dc.date.available | 2021-09-03T00:22:37Z | - |
dc.date.created | 2021-06-19 | - |
dc.date.issued | 2017-10 | - |
dc.identifier.issn | 1996-1073 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/82003 | - |
dc.description.abstract | To increase the utilization of wind power in the power system, grid integration standards have been proposed for the stable integration of large-scale wind power plants. In particular, fault-ride-through capability, especially Low-Voltage-Ride-Through (LVRT), has been emphasized, as it is related to tripping in wind farms. Therefore, this paper proposes the Wind power plant applicable-Effective Reactive power Reserve (Wa-ERPR), which combines both wind power plants and conventional generators at the Point of Interconnection (POI). The reactive power capability of the doubly-fed induction generator wind farm was considered to compute the total Wa-ERPR at the POI with reactive power capability of existing generators. By using the Wa-ERPR management algorithm, in case of a violation of the LVRT standards, the amount of reactive power compensation is computed using the Wa-ERPR management scheme. The proposed scheme calculates the Wa-ERPR and computes the required reactive power, reflecting the change of the system topology pre- and post-contingency, to satisfy the LVRT criterion when LVRT regulation is not satisfied at the POI. The static synchronous compensator (STATCOM) with the capacity corresponding to calculated amount of reactive power through the Wa-ERPR management scheme is applied to the POI. Therefore, it is confirmed that the wind power plant satisfies the LVRT criteria by securing the appropriate reactive power at the POI, by applying of the proposed algorithm. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | MDPI | - |
dc.subject | IMPROVING VOLTAGE STABILITY | - |
dc.subject | COORDINATED CONTROL | - |
dc.subject | WIND TURBINE | - |
dc.subject | SYSTEM | - |
dc.subject | FARM | - |
dc.title | Advanced Reactive Power Reserve Management Scheme to Enhance LVRT Capability | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lee, Byongjun | - |
dc.identifier.doi | 10.3390/en10101540 | - |
dc.identifier.scopusid | 2-s2.0-85044369990 | - |
dc.identifier.wosid | 000414578400095 | - |
dc.identifier.bibliographicCitation | ENERGIES, v.10, no.10 | - |
dc.relation.isPartOf | ENERGIES | - |
dc.citation.title | ENERGIES | - |
dc.citation.volume | 10 | - |
dc.citation.number | 10 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Energy & Fuels | - |
dc.relation.journalWebOfScienceCategory | Energy & Fuels | - |
dc.subject.keywordPlus | IMPROVING VOLTAGE STABILITY | - |
dc.subject.keywordPlus | COORDINATED CONTROL | - |
dc.subject.keywordPlus | WIND TURBINE | - |
dc.subject.keywordPlus | SYSTEM | - |
dc.subject.keywordPlus | FARM | - |
dc.subject.keywordAuthor | low voltage ride through (LVRT) | - |
dc.subject.keywordAuthor | doubly-fed induction generator (DFIG) | - |
dc.subject.keywordAuthor | wind power plant applicable-effective reactive power reserve (Wa-ERPR) | - |
dc.subject.keywordAuthor | voltage control | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.