Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Study protocol for a randomised controlled trial: harmonising optimal strategy for treatment of coronary artery stenosis - coronary intervention with next-generation drug-eluting stent platforms and abbreviated dual antiplatelet therapy (HOST-IDEA) trial

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Chi-Hoon-
dc.contributor.authorHan, Jung-Kyu-
dc.contributor.authorYang, Han-Mo-
dc.contributor.authorPark, Kyung Woo-
dc.contributor.authorLee, Hae-Young-
dc.contributor.authorKang, Hyun-Jae-
dc.contributor.authorKoo, Bon-Kwon-
dc.contributor.authorLee, Namho-
dc.contributor.authorCha, Tae-Joon-
dc.contributor.authorYang, Tae-Hyun-
dc.contributor.authorJeong, Myung-Ho-
dc.contributor.authorYoon, Myeong-Ho-
dc.contributor.authorLee, Seung Uk-
dc.contributor.authorLee, Seung Jin-
dc.contributor.authorKim, Jin Won-
dc.contributor.authorCho, Jin-Man-
dc.contributor.authorHan, Kyu-Rock-
dc.contributor.authorPyun, Wook Bum-
dc.contributor.authorKim, Hyo-Soo-
dc.date.accessioned2021-09-03T00:52:37Z-
dc.date.available2021-09-03T00:52:37Z-
dc.date.created2021-06-19-
dc.date.issued2017-10-
dc.identifier.issn2044-6055-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/82090-
dc.description.abstractIntroduction We have recently seen the introduction of newer generation drug-eluting stents with ultrathin struts that use advanced polymer technologies. However, the efficacy and safety of these newest stents have not yet been fully explored. In addition, there are still controversies over the optimal duration of dual antiplatelet therapy (DAPT) after stent implantation, particularly for ultrathin stents with the newest polymer technologies. Methods and analysis The HOST-IDEA trial is a randomised, open-label, multicentre, non-inferiority trial and the first study to directly compare two of these ultrathin sirolimus-eluting stents: Orsiro stent with biodegradable polymer, and polymerfree Coroflex ISAR (CX-ISAR) stent. This study has a scheme of 2x2 factorial design according to the stent type and DAPT duration (3 vs 12 months). A total of 2152 patients will be randomised and stratified to demonstrate the non-inferiority of CXISAR to Orsiro, or of the abbreviated DAPT duration to the conventional 12 months (both in 1: 1 ratio). For the comparison of stent type, the primary endpoint is target lesion failure (TLF), which is a composite of cardiac death, target vessel-related myocardial infarction and clinically driven target lesion revascularisation. For the comparison of DAPT duration, the net adverse clinical event is the coprimary endpoint, which is defined as a composite of TLF, definite/probable stent thrombosis and major bleeding. Ethic approval and dissemination All the institutions involved in this study are required to have ethical approval prior to patient enrolment. This multicentre study will recruit patients through competitive registration, but institutions that have not yet obtained ethical approvals have made it impossible to enrol patients in a centralised web database. The final results will be presented at relevant international conferences and will be materialised in the form of papers.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherBMJ PUBLISHING GROUP-
dc.subjectASSOCIATION TASK-FORCE-
dc.subjectAMERICAN-COLLEGE-
dc.subjectCLINICAL-TRIALS-
dc.subjectFOLLOW-UP-
dc.subjectDURATION-
dc.subjectEFFICACY-
dc.subjectIMPLANTATION-
dc.subjectDEFINITIONS-
dc.subjectGUIDELINE-
dc.subjectDISEASE-
dc.titleStudy protocol for a randomised controlled trial: harmonising optimal strategy for treatment of coronary artery stenosis - coronary intervention with next-generation drug-eluting stent platforms and abbreviated dual antiplatelet therapy (HOST-IDEA) trial-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Jin Won-
dc.identifier.doi10.1136/bmjopen-2017-016617-
dc.identifier.scopusid2-s2.0-85031322344-
dc.identifier.wosid000422617500093-
dc.identifier.bibliographicCitationBMJ OPEN, v.7, no.10-
dc.relation.isPartOfBMJ OPEN-
dc.citation.titleBMJ OPEN-
dc.citation.volume7-
dc.citation.number10-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaGeneral & Internal Medicine-
dc.relation.journalWebOfScienceCategoryMedicine, General & Internal-
dc.subject.keywordPlusASSOCIATION TASK-FORCE-
dc.subject.keywordPlusAMERICAN-COLLEGE-
dc.subject.keywordPlusCLINICAL-TRIALS-
dc.subject.keywordPlusFOLLOW-UP-
dc.subject.keywordPlusDURATION-
dc.subject.keywordPlusEFFICACY-
dc.subject.keywordPlusIMPLANTATION-
dc.subject.keywordPlusDEFINITIONS-
dc.subject.keywordPlusGUIDELINE-
dc.subject.keywordPlusDISEASE-
dc.subject.keywordAuthorantiplatelet therapy-
dc.subject.keywordAuthorpolymer-
dc.subject.keywordAuthorstent-
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kim, Jin Won photo

Kim, Jin Won
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE