Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Optimization of the injection-port geometries of a vapor injection scroll compressor based on SCOP under various climatic conditions

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Dongwoo-
dc.contributor.authorChung, Hyun Joon-
dc.contributor.authorJeon, Yongseok-
dc.contributor.authorJang, Dong Soo-
dc.contributor.authorKim, Yongchan-
dc.date.accessioned2021-09-03T01:46:10Z-
dc.date.available2021-09-03T01:46:10Z-
dc.date.created2021-06-16-
dc.date.issued2017-09-15-
dc.identifier.issn0360-5442-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/82230-
dc.description.abstractAn analytical study is conducted to optimize the injection-port geometries of a vapor injection asymmetric scroll compressor operating under various climatic conditions. A numerical model was developed to predict the performance of the vapor injection asymmetric scroll compressor in the heating mode according to various operating parameters, and this numerical model was validated using data measured in a vapor injection heat pump. The effects of the location and number of injection ports on the performance of the asymmetric scroll compressor were analyzed using the numerical model. Both the optimal injection-port angle and required injection-port area increased as the outdoor temperature decreased in order to increase the injection mass flow rate. The optimized injection port designs were then proposed for the asymmetric scroll compressor in order to achieve the maximum SCOP (seasonal coefficient of performance) under various climatic conditions, improving the SCOP by 2%-6% relative to the baseline injection compressor. (C) 2017 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.subjectHEAT-PUMP SYSTEMS-
dc.subjectREFRIGERANT INJECTION-
dc.subjectPERFORMANCE-
dc.subjectMODEL-
dc.titleOptimization of the injection-port geometries of a vapor injection scroll compressor based on SCOP under various climatic conditions-
dc.typeArticle-
dc.contributor.affiliatedAuthorJang, Dong Soo-
dc.contributor.affiliatedAuthorKim, Yongchan-
dc.identifier.doi10.1016/j.energy.2017.06.153-
dc.identifier.scopusid2-s2.0-85021416937-
dc.identifier.wosid000412043300040-
dc.identifier.bibliographicCitationENERGY, v.135, pp.442 - 454-
dc.relation.isPartOfENERGY-
dc.citation.titleENERGY-
dc.citation.volume135-
dc.citation.startPage442-
dc.citation.endPage454-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.subject.keywordPlusHEAT-PUMP SYSTEMS-
dc.subject.keywordPlusREFRIGERANT INJECTION-
dc.subject.keywordPlusPERFORMANCE-
dc.subject.keywordPlusMODEL-
dc.subject.keywordAuthorVapor injection-
dc.subject.keywordAuthorHeat pump-
dc.subject.keywordAuthorInjection port-
dc.subject.keywordAuthorSCOP-
dc.subject.keywordAuthorScroll compressor-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher KIM, Yong Chan photo

KIM, Yong Chan
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE