Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Diagnostic accuracy of dual-energy computed tomography in patients with gout: A meta-analysis

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Young Ho-
dc.contributor.authorSong, Gwan Gyu-
dc.date.accessioned2021-09-03T03:19:48Z-
dc.date.available2021-09-03T03:19:48Z-
dc.date.created2021-06-16-
dc.date.issued2017-08-
dc.identifier.issn0049-0172-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/82642-
dc.description.abstractObjective: This study aimed to evaluate the diagnostic performance of dual-energy computed tomography (DECT) for patients with gout. Methods: We searched the Medline, Embase, and Cochrane Library databases, and performed a meta analysis on the diagnostic accuracy of DECT in patients with gout. Results: A total of eight studies including 510 patients with gout and 268 controls (patients with non gout inflammatory arthritis) were available for the meta-analysis. The pooled sensitivity and specificity of DECT were 84.7% (95% confidence interval [CI]: 81.3-87.7) and 93.7% (93.0-96.3), respectively. The positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 9.882 (6.122-15.95), 0.163 (0.097-0.272), and 78.10 (31.14-195.84), respectively. The area under the curve of DECT was 0.956 and the Q(*) index was 0.889, indicating a high diagnostic accuracy. Some between-study heterogeneity was found in the meta-analyses. However, there was no evidence of a threshold effect (Spearman correlation coefficient = 0.419; p = 0.035). In addition, meta-regression showed that the sample size, study design, and diagnostic criteria were not sources of heterogeneity, and subgroup meta-analyses did not change the overall diagnostic accuracy. Conclusions: Our meta-analysis of published studies demonstrates that DECT has a high diagnostic accuracy and plays an important role in the diagnosis of gout. (C) 2017 Elsevier Inc. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherW B SAUNDERS CO-ELSEVIER INC-
dc.subjectURIC-ACID-
dc.subjectAMERICAN-COLLEGE-
dc.subjectCT-
dc.subjectCLASSIFICATION-
dc.subjectHYPERURICEMIA-
dc.subjectHETEROGENEITY-
dc.subjectCRITERIA-
dc.subjectBIAS-
dc.titleDiagnostic accuracy of dual-energy computed tomography in patients with gout: A meta-analysis-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Young Ho-
dc.contributor.affiliatedAuthorSong, Gwan Gyu-
dc.identifier.doi10.1016/j.semarthrit.2017.03.002-
dc.identifier.scopusid2-s2.0-85016262835-
dc.identifier.wosid000407411400011-
dc.identifier.bibliographicCitationSEMINARS IN ARTHRITIS AND RHEUMATISM, v.47, no.1, pp.95 - 101-
dc.relation.isPartOfSEMINARS IN ARTHRITIS AND RHEUMATISM-
dc.citation.titleSEMINARS IN ARTHRITIS AND RHEUMATISM-
dc.citation.volume47-
dc.citation.number1-
dc.citation.startPage95-
dc.citation.endPage101-
dc.type.rimsART-
dc.type.docTypeReview-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRheumatology-
dc.relation.journalWebOfScienceCategoryRheumatology-
dc.subject.keywordPlusURIC-ACID-
dc.subject.keywordPlusAMERICAN-COLLEGE-
dc.subject.keywordPlusCT-
dc.subject.keywordPlusCLASSIFICATION-
dc.subject.keywordPlusHYPERURICEMIA-
dc.subject.keywordPlusHETEROGENEITY-
dc.subject.keywordPlusCRITERIA-
dc.subject.keywordPlusBIAS-
dc.subject.keywordAuthorGout-
dc.subject.keywordAuthorDECT-
dc.subject.keywordAuthorDiagnostic accuracy-
dc.subject.keywordAuthorMeta-analysis-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Young Ho photo

Lee, Young Ho
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE