Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Ultrasonographic and Electrophysiological Evaluation of Ulnar Nerve Instability and Snapping of the Triceps Medial Head in Healthy Subjects

Full metadata record
DC Field Value Language
dc.contributor.authorKang, Jae Ho-
dc.contributor.authorJoo, Byung-Euk-
dc.contributor.authorKim, Ki Hoon-
dc.contributor.authorPark, Byung Kyu-
dc.contributor.authorCha, Jaehyung-
dc.contributor.authorKim, Dong Hwee-
dc.date.accessioned2021-09-03T03:23:50Z-
dc.date.available2021-09-03T03:23:50Z-
dc.date.created2021-06-16-
dc.date.issued2017-08-
dc.identifier.issn0894-9115-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/82667-
dc.description.abstractObjective To evaluate the relationship between ulnar nerve instability and snapping of the triceps medial head during elbow flexion. Designs Twenty-six healthy individuals were recruited. The primary outcome measures were ultrasonographic and electrophysiological parameters of the ulnar nerve. Ulnar nerve instability was classified into three types based on the degree of ulnar nerve movement: no dislocation (Type N), subluxation (Type S), and dislocation (Type D). Results In the elbow 90-degree position, the incidences of Type N, S, and D were 41 (78.8%), 8 (15.4%), and 3 (5.8%) elbows, respectively; in the full flexion position, the incidences of Types N, S, and D were 24 (46.2%), 19 (36.5%), and 9 (17.3%) elbows, respectively. Spearman's correlation coefficients between ulnar nerve instability and snapping of the triceps medial head in the elbow 90-degree and full flexion positions were 0.808 and 0.889 (P < 0.001), respectively. The ulnar sensory response in Type S was of prolonged latency and decreased amplitude compared with that in Type N or D in the elbow full flexion position. Conclusions Ulnar nerve instability increased with elbow flexion and correlated with snapping of the triceps medial head. Ultrasonography of the ulnar nerve is an important tool in ulnar nerve instability assessment.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherLIPPINCOTT WILLIAMS & WILKINS-
dc.subjectCUBITAL TUNNEL-
dc.subjectDISLOCATION-
dc.titleUltrasonographic and Electrophysiological Evaluation of Ulnar Nerve Instability and Snapping of the Triceps Medial Head in Healthy Subjects-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Ki Hoon-
dc.contributor.affiliatedAuthorPark, Byung Kyu-
dc.contributor.affiliatedAuthorKim, Dong Hwee-
dc.identifier.doi10.1097/PHM.0000000000000706-
dc.identifier.scopusid2-s2.0-85011664803-
dc.identifier.wosid000405783800014-
dc.identifier.bibliographicCitationAMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION, v.96, no.8, pp.e141 - e146-
dc.relation.isPartOfAMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION-
dc.citation.titleAMERICAN JOURNAL OF PHYSICAL MEDICINE & REHABILITATION-
dc.citation.volume96-
dc.citation.number8-
dc.citation.startPagee141-
dc.citation.endPagee146-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaRehabilitation-
dc.relation.journalResearchAreaSport Sciences-
dc.relation.journalWebOfScienceCategoryRehabilitation-
dc.relation.journalWebOfScienceCategorySport Sciences-
dc.subject.keywordPlusCUBITAL TUNNEL-
dc.subject.keywordPlusDISLOCATION-
dc.subject.keywordAuthorUlnar Nerve-
dc.subject.keywordAuthorInstability-
dc.subject.keywordAuthorTriceps Brachii-
dc.subject.keywordAuthorUltrasonography-
dc.subject.keywordAuthorElectrodiagnosis-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE