AC Transmission Emulation Control Strategies for the BTB VSC HVDC System in the Metropolitan Area of Seoul
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Song, Sungyoon | - |
dc.contributor.author | Kim, Jongin | - |
dc.contributor.author | Lee, Junghun | - |
dc.contributor.author | Jang, Gilsoo | - |
dc.date.accessioned | 2021-09-03T03:36:02Z | - |
dc.date.available | 2021-09-03T03:36:02Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2017-08 | - |
dc.identifier.issn | 1996-1073 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/82734 | - |
dc.description.abstract | In the Korean power system, growing power loads have recently created the problems of voltage instability and fault current in the Seoul Capital Area (SCA). Accordingly, the back-to-back (BTB) voltage source converter (VSC) high-voltage direct-current (HVDC) system is emerging to resolve such problems with grid segmentation. However, non-convergence problems occur in this metropolitan area, due to the large change of power flow in some contingencies. Therefore, this paper proposes two kinds of AC transmission emulation control (ATEC) strategies to improve the metropolitan transient stability, and to resolve the non-convergence problem. The proposed ATEC strategies are able to mitigate possible overloading of adjacent AC transmission, and maintain power balance between metropolitan regions. The first ATEC strategy uses a monitoring system that permits the reverse power flow of AC transmission, and thus effectively improves the grid stability based on the power transfer equation. The second ATEC strategy emulates AC transmission with DC link capacitors in a permissible DC-link voltage range according to angle difference, and securely improves the gird stability, without requiring grid operator schedule decisions. This paper compares two kinds of ATEC schemes: it demonstrates the first ATEC strategy with specific fault scenario with PSS/E (Power Transmission System Planning Software), and evaluates the second ATEC strategy with internal controller performance with PSCAD/EMTDC (Power System Electromagnetic Transients Simulation Software). | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | MDPI | - |
dc.title | AC Transmission Emulation Control Strategies for the BTB VSC HVDC System in the Metropolitan Area of Seoul | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Jang, Gilsoo | - |
dc.identifier.doi | 10.3390/en10081143 | - |
dc.identifier.scopusid | 2-s2.0-85044398341 | - |
dc.identifier.wosid | 000407436700071 | - |
dc.identifier.bibliographicCitation | ENERGIES, v.10, no.8 | - |
dc.relation.isPartOf | ENERGIES | - |
dc.citation.title | ENERGIES | - |
dc.citation.volume | 10 | - |
dc.citation.number | 8 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Energy & Fuels | - |
dc.relation.journalWebOfScienceCategory | Energy & Fuels | - |
dc.subject.keywordAuthor | back-to-back HVDC | - |
dc.subject.keywordAuthor | AC transmission emulation control | - |
dc.subject.keywordAuthor | voltage source converter | - |
dc.subject.keywordAuthor | angle difference | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.