Long-term clinical outcomes of the single-incision technique for implantation of implantable venous access ports via the axillary vein

Full metadata record
DC Field Value Language
dc.contributor.authorSeo, Tae-Seok-
dc.contributor.authorSong, Myung Gyu-
dc.contributor.authorKim, Jun Suk-
dc.contributor.authorChoi, Chul Won-
dc.contributor.authorSeo, Jae Hong-
dc.contributor.authorOh, Sang Cheul-
dc.contributor.authorKang, Eun Joo-
dc.contributor.authorLee, Jae-Kwan-
dc.contributor.authorLee, Sung-yong-
dc.date.accessioned2021-09-03T04:34:08Z-
dc.date.available2021-09-03T04:34:08Z-
dc.date.created2021-06-16-
dc.date.issued2017-07-
dc.identifier.issn1129-7298-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/82996-
dc.description.abstractPurpose: To evaluate long-term clinical outcomes and complications of the single-incision technique for implantation of totally implantable venous access ports (TIVAPs) via the axillary vein. Materials and methods: A total of 932 TIVAPs were placed in 927 patients between May 2012 and October 2014 using a single-incision technique. Patients included 620 men and 307 women with a mean age of 60.0 years. TIVAPs were placed via the left (n = 475) and right (n = 457) axillary veins after making a single oblique vertical incision and medial side pocket without subcutaneous tunneling. We retrospectively reviewed medical records to evaluate status of the patients and TIVAPs, complications, and reasons for explantation. In patients who still had a TIVAP in place, we calculated the duration of TIVAP use from the cut-off day of November 1, 2015. Results: Clinical follow-up was obtained for a total device service period of 311,069 days with a median indwelling time of 467 days (range: 3-1097 days). A total of 37 (4.0%) complications developed. Early complications (n = 4) were one case each of stenosis of the brachiocephalic vein by tumor growth, thrombosis of axillary vein, intravascular migration, and malfunction depending on patient's position. Late complications (n = 33) were suspected catheter-related blood stream infection (n = 23), local infection of the pocket (n = 4), symptomatic stenosis and thrombosis of central vein (n = 4), malfunction by fibrin sleeve (n = 1), and intravascular migration (n = 1). Conclusions: A single-incision technique for TIVAP implantation via the axillary vein seems to be safe with a low risk of complication.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherSAGE PUBLICATIONS LTD-
dc.subjectMULTIVARIATE-ANALYSIS-
dc.subjectDEVICES-
dc.subjectCOMPLICATIONS-
dc.subjectULTRASOUND-
dc.subjectPLACEMENT-
dc.subjectCANNULATION-
dc.subjectEXPERIENCE-
dc.subjectCATHETERS-
dc.subjectFIXATION-
dc.subjectSYSTEMS-
dc.titleLong-term clinical outcomes of the single-incision technique for implantation of implantable venous access ports via the axillary vein-
dc.typeArticle-
dc.contributor.affiliatedAuthorSeo, Tae-Seok-
dc.contributor.affiliatedAuthorSong, Myung Gyu-
dc.contributor.affiliatedAuthorKim, Jun Suk-
dc.contributor.affiliatedAuthorChoi, Chul Won-
dc.contributor.affiliatedAuthorSeo, Jae Hong-
dc.contributor.affiliatedAuthorOh, Sang Cheul-
dc.contributor.affiliatedAuthorKang, Eun Joo-
dc.contributor.affiliatedAuthorLee, Jae-Kwan-
dc.contributor.affiliatedAuthorLee, Sung-yong-
dc.identifier.doi10.5301/jva.5000751-
dc.identifier.scopusid2-s2.0-85024474984-
dc.identifier.wosid000405846500014-
dc.identifier.bibliographicCitationJOURNAL OF VASCULAR ACCESS, v.18, no.4, pp.345 - 351-
dc.relation.isPartOfJOURNAL OF VASCULAR ACCESS-
dc.citation.titleJOURNAL OF VASCULAR ACCESS-
dc.citation.volume18-
dc.citation.number4-
dc.citation.startPage345-
dc.citation.endPage351-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaCardiovascular System & Cardiology-
dc.relation.journalWebOfScienceCategoryPeripheral Vascular Disease-
dc.subject.keywordPlusMULTIVARIATE-ANALYSIS-
dc.subject.keywordPlusDEVICES-
dc.subject.keywordPlusCOMPLICATIONS-
dc.subject.keywordPlusULTRASOUND-
dc.subject.keywordPlusPLACEMENT-
dc.subject.keywordPlusCANNULATION-
dc.subject.keywordPlusEXPERIENCE-
dc.subject.keywordPlusCATHETERS-
dc.subject.keywordPlusFIXATION-
dc.subject.keywordPlusSYSTEMS-
dc.subject.keywordAuthorAxillary vein-
dc.subject.keywordAuthorComplications-
dc.subject.keywordAuthorImplantable venous access port-
dc.subject.keywordAuthorSingle-incision technique-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lee, Jae Kwan photo

Lee, Jae Kwan
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE