Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Generation of digitized microfluidic filling flow by vent control

Full metadata record
DC Field Value Language
dc.contributor.authorYoon, Junghyo-
dc.contributor.authorLee, Eundoo-
dc.contributor.authorKim, Jaehoon-
dc.contributor.authorHan, Sewoon-
dc.contributor.authorChung, Seok-
dc.date.accessioned2021-09-03T04:59:58Z-
dc.date.available2021-09-03T04:59:58Z-
dc.date.created2021-06-16-
dc.date.issued2017-06-15-
dc.identifier.issn0956-5663-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/83126-
dc.description.abstractQuantitative microfluidic point-of-care testing has been translated into clinical applications to support a prompt decision on patient treatment. A nanointerstice-driven filling technique has been developed to realize the fast and robust filling of microfluidic channels with liquid samples, but it has failed to provide a consistent filling time owing to the wide variation in liquid viscosity, resulting in an increase in quantification errors. There is a strong demand for simple and quick flow control to ensure accurate quantification, without a serious increase in system complexity. A new control mechanism employing two-beam refraction and one solenoid valve was developed and found to successfully generate digitized filling flow, completely free from errors due to changes in viscosity. The validity of digitized filling flow was evaluated by the immunoassay, using liquids with a wide range of viscosity. This digitized microfluidic filling flow is a novel approach that could be applied in conventional microfluidic point-of-care testing.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER ADVANCED TECHNOLOGY-
dc.subjectON-A-CHIP-
dc.subjectIMMUNOCHROMATOGRAPHIC ASSAY-
dc.subjectPOINT-
dc.subjectIMMUNOASSAY-
dc.subjectALBUMIN-
dc.titleGeneration of digitized microfluidic filling flow by vent control-
dc.typeArticle-
dc.contributor.affiliatedAuthorChung, Seok-
dc.identifier.doi10.1016/j.bios.2016.10.079-
dc.identifier.scopusid2-s2.0-85006761845-
dc.identifier.wosid000396946600064-
dc.identifier.bibliographicCitationBIOSENSORS & BIOELECTRONICS, v.92, pp.465 - 471-
dc.relation.isPartOfBIOSENSORS & BIOELECTRONICS-
dc.citation.titleBIOSENSORS & BIOELECTRONICS-
dc.citation.volume92-
dc.citation.startPage465-
dc.citation.endPage471-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaBiophysics-
dc.relation.journalResearchAreaBiotechnology & Applied Microbiology-
dc.relation.journalResearchAreaChemistry-
dc.relation.journalResearchAreaElectrochemistry-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryBiophysics-
dc.relation.journalWebOfScienceCategoryBiotechnology & Applied Microbiology-
dc.relation.journalWebOfScienceCategoryChemistry, Analytical-
dc.relation.journalWebOfScienceCategoryElectrochemistry-
dc.relation.journalWebOfScienceCategoryNanoscience & Nanotechnology-
dc.subject.keywordPlusON-A-CHIP-
dc.subject.keywordPlusIMMUNOCHROMATOGRAPHIC ASSAY-
dc.subject.keywordPlusPOINT-
dc.subject.keywordPlusIMMUNOASSAY-
dc.subject.keywordPlusALBUMIN-
dc.subject.keywordAuthorNanointerstice-
dc.subject.keywordAuthorMicrofluidic channel filling-
dc.subject.keywordAuthorDigitized fluidic filling-
dc.subject.keywordAuthorImmunoassay-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Chung, Seok photo

Chung, Seok
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE