Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Performance of a Two-Phase Injection Heat Pump with the Variation of Injection Quality and Pressure

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Bo Gyeom-
dc.contributor.authorKim, Dongwoo-
dc.contributor.authorLee, Dongchan-
dc.contributor.authorKim, Yongchan-
dc.date.accessioned2021-09-03T05:27:30Z-
dc.date.available2021-09-03T05:27:30Z-
dc.date.created2021-06-16-
dc.date.issued2017-06-
dc.identifier.issn2010-1325-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/83237-
dc.description.abstractHeat pumps are becoming more commonly and widely used due to their advantages in efficiency and versatile applications in both cooling and heating. However, the reliability of its compressor is being compromised due to high discharge temperatures caused by harsh operating conditions. Among the numerous studies conducted in improving the discharge temperature and performance of the heat pump, two-phase injection is receiving great interest. In this study, the performance of the two-phase injection heat pump was measured with a variation of operating parameters. The experiment results were used to study the performance change according to the operating parameter such as injection quality and pressure. It was found that the performance of the heat pump using the two-phase injection was better in terms of COP by up to 5.8% compared to that using the vapor injection. Furthermore, the two-phase injection was er effective in reducing the discharge temperature to improve the compressor reliability. Two types of optimum injection qualities were suggested through this study: discharge temperature optimum injection quality (TIQ), and performance optimum injection quality (PIQ). It was found that in most conditions PIQ was sufficient in satisfying the compressor reliability, but in harsh operating conditions, where the compression ratio was high, TIQ was required in order to maintain the compressor reliability.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherWORLD SCIENTIFIC PUBL CO PTE LTD-
dc.subjectSCROLL COMPRESSOR-
dc.subjectSATURATION CYCLE-
dc.subjectREFRIGERANT-
dc.titlePerformance of a Two-Phase Injection Heat Pump with the Variation of Injection Quality and Pressure-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Yongchan-
dc.identifier.doi10.1142/S2010132517500183-
dc.identifier.scopusid2-s2.0-85019207313-
dc.identifier.wosid000402995000009-
dc.identifier.bibliographicCitationINTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, v.25, no.2-
dc.relation.isPartOfINTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION-
dc.citation.titleINTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION-
dc.citation.volume25-
dc.citation.number2-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.identifier.kciidART002233221-
dc.description.journalClass1-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.subject.keywordPlusSCROLL COMPRESSOR-
dc.subject.keywordPlusSATURATION CYCLE-
dc.subject.keywordPlusREFRIGERANT-
dc.subject.keywordAuthorHeat pump-
dc.subject.keywordAuthortwo-phase injection-
dc.subject.keywordAuthorinjection quality-
dc.subject.keywordAuthorcompressor reliability-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher KIM, Yong Chan photo

KIM, Yong Chan
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE