Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Radiation Dose from Whole-Body F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: Nationwide Survey in Korea

Full metadata record
DC Field Value Language
dc.contributor.authorKwon, Hyun Woo-
dc.contributor.author권현우-
dc.date.accessioned2021-09-03T07:31:04Z-
dc.date.available2021-09-03T07:31:04Z-
dc.date.created2021-06-21-
dc.date.issued2016-02-
dc.identifier.issn1011-8934-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/83839-
dc.description.abstractThe purpose of this study was to estimate average radiation exposure from F-18-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) examinations and to analyze possible factors affecting the radiation dose. A nationwide questionnaire survey was conducted involving all institutions that operate PET/CT scanners in Korea. From the response, radiation doses from injected FDG and CT examination were calculated. A total of 105 PET/CT scanners in 73 institutions were included in the analysis (response rate of 62.4%). The average FDG injected activity was 310 +/- 77 MBq and 5.11 +/- 1.19 MBq/kg. The average effective dose from FDG was estimated to be 5.89 +/- 1.46 mSv. The average CT dose index and dose-length product were 4.60 +/- 2.47 mGy and 429.2 +/- 227.6 mGy.cm, which corresponded to 6.26 +/- 3.06 mSv. The radiation doses from FDG and CT were significantly lower in case of newer scanners than older ones (P < 0.001). Advanced PET technologies such as time-of-flight acquisition and point-spread function recovery were also related to low radiation dose (P < 0.001). In conclusion, the average radiation dose from FDG PET/CT is estimated to be 12.2 mSv. The radiation dose from FDG PET/CT is reduced with more recent scanners equipped with image-enhancing algo-
dc.languageEnglish-
dc.language.isoen-
dc.publisherKOREAN ACAD MEDICAL SCIENCES-
dc.titleRadiation Dose from Whole-Body F-18 Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography: Nationwide Survey in Korea-
dc.typeArticle-
dc.contributor.affiliatedAuthorKwon, Hyun Woo-
dc.contributor.affiliatedAuthor권현우-
dc.identifier.doi10.3346/jkms.2016.31.S1.S69-
dc.identifier.bibliographicCitationJOURNAL OF KOREAN MEDICAL SCIENCE, v.31, pp.69 - 74-
dc.relation.isPartOfJOURNAL OF KOREAN MEDICAL SCIENCE-
dc.citation.titleJOURNAL OF KOREAN MEDICAL SCIENCE-
dc.citation.volume31-
dc.citation.startPage69-
dc.citation.endPage74-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.description.journalRegisteredClasskci-
dc.subject.keywordAuthorFDG PET/CT-
dc.subject.keywordAuthorRadiation Exposure-
dc.subject.keywordAuthorNational Survey-
dc.subject.keywordAuthorDose Reference Level-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE