Development of a Double-Gauss Lens Based Setup for Optoacoustic Applications
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Choi, Hojong | - |
dc.contributor.author | Ryu, Jae-Myung | - |
dc.contributor.author | Yeom, Jung-Yeol | - |
dc.date.accessioned | 2021-09-03T08:55:01Z | - |
dc.date.available | 2021-09-03T08:55:01Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2017-03 | - |
dc.identifier.issn | 1424-8220 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/84261 | - |
dc.description.abstract | In optoacoustic (photoacoustic) systems, different echo signal intensities such as amplitudes, center frequencies, and bandwidths need to be compensated by utilizing variable gain or time-gain compensation amplifiers. However, such electronic components can increase system complexities and signal noise levels. In this paper, we introduce a double-Gauss lens to generate a large field of view with uniform light intensity due to the low chromatic aberrations of the lens, thus obtaining uniform echo signal intensities across the field of view of the optoacoustic system. In order to validate the uniformity of the echo signal intensities in the system, an in-house transducer was placed at various positions above a tissue sample and echo signals were measured and compared with each other. The custom designed double-Gauss lens demonstrated negligible light intensity variation (+/- 1.5%) across the illumination field of view (similar to 2 cm diameter). When the transducer was used to measure echo signal from an eye of a bigeye tuna within a range of +/- 1 cm, the peak-to-peak amplitude, center frequency, and their -6 dB bandwidth variations were less than 2 mV, 1 MHz, and 6%, respectively. The custom designed double-Gauss lens can provide uniform light beam across a wide area while generating insignificant echo signal variations, and thus can lower the burden of the receiving electronics or signal processing in the optoacoustic system. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | MDPI | - |
dc.subject | PHOTOACOUSTIC MICROSCOPY | - |
dc.subject | IN-VIVO | - |
dc.subject | ULTRASOUND | - |
dc.subject | FREQUENCY | - |
dc.subject | DESIGN | - |
dc.subject | TRANSDUCERS | - |
dc.title | Development of a Double-Gauss Lens Based Setup for Optoacoustic Applications | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yeom, Jung-Yeol | - |
dc.identifier.doi | 10.3390/s17030496 | - |
dc.identifier.scopusid | 2-s2.0-85014623248 | - |
dc.identifier.wosid | 000398818700069 | - |
dc.identifier.bibliographicCitation | SENSORS, v.17, no.3 | - |
dc.relation.isPartOf | SENSORS | - |
dc.citation.title | SENSORS | - |
dc.citation.volume | 17 | - |
dc.citation.number | 3 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Instruments & Instrumentation | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Analytical | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Instruments & Instrumentation | - |
dc.subject.keywordPlus | PHOTOACOUSTIC MICROSCOPY | - |
dc.subject.keywordPlus | IN-VIVO | - |
dc.subject.keywordPlus | ULTRASOUND | - |
dc.subject.keywordPlus | FREQUENCY | - |
dc.subject.keywordPlus | DESIGN | - |
dc.subject.keywordPlus | TRANSDUCERS | - |
dc.subject.keywordAuthor | optoacoustic applications | - |
dc.subject.keywordAuthor | double-Gauss lens | - |
dc.subject.keywordAuthor | transducer | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.