International Electronical Committee (IEC) 61850 Mapping with Constrained Application Protocol (CoAP) in Smart Grids Based European Telecommunications Standard Institute Machine-to-Machine (M2M) Environment
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Shin, In-Jae | - |
dc.contributor.author | Song, Byung-Kwen | - |
dc.contributor.author | Eom, Doo-Seop | - |
dc.date.accessioned | 2021-09-03T09:15:13Z | - |
dc.date.available | 2021-09-03T09:15:13Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2017-03 | - |
dc.identifier.issn | 1996-1073 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/84373 | - |
dc.description.abstract | As power systems develop rapidly into smarter and more flexible configurations, so too must the communication technologies that support them. Machine-to-machine (M2M) communication in power systems enables information collection by combining sensors and communication protocols. In doing so, M2M technology supports communication between machines to improve power quality and protection coordination. When functioning in a smart grid environment, M2M has been labelled by the European Telecommunications Standard Institute (ETSI). International Electronical Committee (IEC) 61850 as the most important standard in power network systems. As evidence, this communication platform has been used for device data collection/control in substation automation systems and distribution automation systems. If the IEC 61850 information model were to be combined with a set of contemporary web protocols, the potential benefits would be enormous. Therefore, a constrained application protocol (CoAP) has been adopted to create an ETSI M2M communication architecture. CoAP is compared with other protocols (MQTT, SOAP) to demonstrate the validity of using it. This M2M communication technology is applied in an IEC61850, and use the OPNET Modeler 17.1 to demonstrate intercompatibility of CoAP Gateway. The proposed IEC 61850 and CoAP mapping scheme reduces the mapping time and improves throughput. CoAP is useful in the ETSI M2M environment where device capability is able to be limited. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | MDPI AG | - |
dc.title | International Electronical Committee (IEC) 61850 Mapping with Constrained Application Protocol (CoAP) in Smart Grids Based European Telecommunications Standard Institute Machine-to-Machine (M2M) Environment | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Eom, Doo-Seop | - |
dc.identifier.doi | 10.3390/en10030393 | - |
dc.identifier.scopusid | 2-s2.0-85025473657 | - |
dc.identifier.wosid | 000398736700133 | - |
dc.identifier.bibliographicCitation | ENERGIES, v.10, no.3 | - |
dc.relation.isPartOf | ENERGIES | - |
dc.citation.title | ENERGIES | - |
dc.citation.volume | 10 | - |
dc.citation.number | 3 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Energy & Fuels | - |
dc.relation.journalWebOfScienceCategory | Energy & Fuels | - |
dc.subject.keywordAuthor | IEC 61850 | - |
dc.subject.keywordAuthor | constrained application protocol (CoAP) | - |
dc.subject.keywordAuthor | gateway | - |
dc.subject.keywordAuthor | smart grid | - |
dc.subject.keywordAuthor | machine-to-machine (M2M) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.