dc.description.abstractWe have estimated the secondary cancer risk (SCR) introduced by image-guided procedures during proton therapy. The physical dose from imaging radiation and the corresponding organ equivalent dose were calculated for the case of a lumbar spine patient. The maximum physical dose delivered to the patient during the imaging procedure was estimated to be similar to 0.35% of the prescribed dose of 46 Gy. However, this small imaging dose substantially raised the radiation-induced SCR by similar to 8%. In addition, the clinical benefit (improved accuracy during the procedure) and costs (extra SCR) associated with image-guided procedures were quantitatively modelled by systematically investigating the changes in SCR as a function of the prescribed dose, treatment target volume and imaging field size. The results showed that the SCR varied sensitively with the volume receiving the imaging and the therapeutic radiation, whereas the SCR depended to a lesser extent on the magnitude of the applied therapeutic radiation. These results showed that the additional SCR introduced by imaging radiation could be efficiently reduced by minimizing the imaging field size during image-guided procedures.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherIOP PUBLISHING LTD-
dc.titleEstimation of the secondary cancer risk induced by diagnostic imaging radiation during proton therapy-
dc.typeArticle-
dc.contributor.affiliatedAuthor정호진-
dc.contributor.affiliatedAuthorYoon, Myonggeun-
dc.identifier.bibliographicCitationJOURNAL OF RADIOLOGICAL PROTECTION, v.31, no.4, pp.477 - 487-
dc.relation.isPartOfJOURNAL OF RADIOLOGICAL PROTECTION-
dc.citation.titleJOURNAL OF RADIOLOGICAL PROTECTION-
dc.citation.volume31-
dc.citation.number4-
dc.citation.startPage477-
dc.citation.endPage487-
dc.type.rimsART-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Biomedical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Yoon, Myong geun photo

Yoon, Myong geun
보건과학대학 (바이오의공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE