Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The Usefulness of Dynamic Cine-Arthrography for Wrist Instability as Correlated with Arthroscopic Palmer Classification

Full metadata record
DC Field Value Language
dc.contributor.authorBo Kyoung Seo-
dc.contributor.authorCHA SANG HOON-
dc.contributor.authorKim Baek Hyun-
dc.contributor.authorPARK, Jong Woong-
dc.date.accessioned2021-09-03T10:00:54Z-
dc.date.available2021-09-03T10:00:54Z-
dc.date.created2021-06-21-
dc.date.issued2011-03-
dc.identifier.issn1738-2637-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/84629-
dc.description.abstractPurpose: To introduce dynamic cine-arthrography and compare it with MR arthrography in the diagnosis of intrinsic ligament and triangular fibrocartilage complex tears, based on arthroscopic findings. Materials and Methods: A total of thirty-eight wrists of 38 patients who had undergone both dynamic cine-arthrography and MR arthrography were enrolled. Dynamic cinearthrography was performed after puncture of the radiocarpal joint by slow injection of contrast under continuous fluoroscopic guidance during passive wrist exercise. We obtained 1.5- or 3-T MR arthrography with fat-suppressed T1-weighted coronal and axial images. We evaluated scapholunate and lunotriquetral ligaments and triangular fibrocartilage complex tears according to the Palmer classification system. Based on the arthroscopic findings, we compared the diagnostic values between the two examinations using Kappa values. Results: The overall sensitivity and specificity of diagnosis of intrinsic ligament tears was similar between dynamic cine-arthrography and MR arthrography (scapholunate ligament: sensitivity 66.7% vs. 80%, specificity 100% vs. 95.7%, lunotriquetral ligament: sensitivity 75.0% vs. 75.0%, specificity 94.1% vs. 91.2%). For triangular fibrocartilage complex tears, all diagnostic values were the same (se-
dc.languageEnglish-
dc.language.isoen-
dc.publisher대한영상의학회-
dc.titleThe Usefulness of Dynamic Cine-Arthrography for Wrist Instability as Correlated with Arthroscopic Palmer Classification-
dc.title.alternative관절경 소견의 팔마체계와 비교한 손목관절 불안정성에 대한 동영상관절조영술의 유용성-
dc.typeArticle-
dc.contributor.affiliatedAuthorBo Kyoung Seo-
dc.contributor.affiliatedAuthorCHA SANG HOON-
dc.contributor.affiliatedAuthorKim Baek Hyun-
dc.contributor.affiliatedAuthorPARK, Jong Woong-
dc.identifier.bibliographicCitation대한영상의학회지, v.64, no.3, pp.265 - 271-
dc.relation.isPartOf대한영상의학회지-
dc.citation.title대한영상의학회지-
dc.citation.volume64-
dc.citation.number3-
dc.citation.startPage265-
dc.citation.endPage271-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass2-
dc.description.journalRegisteredClasskci-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles
Graduate School > Department of Biomedical Sciences > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Altmetrics

Total Views & Downloads