고온에 노출된 PCM 충진형 바닥 시스템의 거동 특성
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 박민재 | - |
dc.contributor.author | 민정기 | - |
dc.contributor.author | 윤성원 | - |
dc.contributor.author | 주영규 | - |
dc.date.accessioned | 2021-09-03T13:56:00Z | - |
dc.date.available | 2021-09-03T13:56:00Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2017 | - |
dc.identifier.issn | 1598-4095 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/86027 | - |
dc.description.abstract | Composite Floor system infilled with PCM(Phase Change Material) between upper and lower steel plates was developed to apply the steel frame. When steel frames were applied this system, it can absolutely reduce the duration of construction due to dry construction method. However to apply this system as a structural floor member without fire resistance covering, it must have 2 hours fire resistance performance. Because PCM consisted of three quarters of section with thermal insulation performance, fire resistance performance of this floor system was expected to easily have 2 hours fire resistance performance. This paper was to investigate behavior characteristics of PCM infilled floor system at elevated temperature using FEM analysis to develop the fire resistance performance of it. | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 한국공간구조학회 | - |
dc.title | 고온에 노출된 PCM 충진형 바닥 시스템의 거동 특성 | - |
dc.title.alternative | Behavior Characteristics of PCM Infilled Floor System at Elevated Temperature | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 주영규 | - |
dc.identifier.doi | 10.9712/KASS.2017.17.2.033 | - |
dc.identifier.bibliographicCitation | 한국공간구조학회지, v.17, no.2, pp.33 - 41 | - |
dc.relation.isPartOf | 한국공간구조학회지 | - |
dc.citation.title | 한국공간구조학회지 | - |
dc.citation.volume | 17 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 33 | - |
dc.citation.endPage | 41 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002230652 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | PCM | - |
dc.subject.keywordAuthor | Fire resistance performance | - |
dc.subject.keywordAuthor | Fire furnace test | - |
dc.subject.keywordAuthor | Composite floor system | - |
dc.subject.keywordAuthor | Steel frame | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.