Single cardiac cycle three-dimensional intracoronary optical coherence tomography
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Tae Shik | - |
dc.contributor.author | Park, Hyun-Sang | - |
dc.contributor.author | Jang, Sun-Joo | - |
dc.contributor.author | Song, Joon Woo | - |
dc.contributor.author | Cho, Han Saem | - |
dc.contributor.author | Kim, Sunwon | - |
dc.contributor.author | Bouma, Brett E. | - |
dc.contributor.author | Kim, Jin Won | - |
dc.contributor.author | Oh, Wang-Yuhl | - |
dc.date.accessioned | 2021-09-03T15:58:51Z | - |
dc.date.available | 2021-09-03T15:58:51Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2016-12-01 | - |
dc.identifier.issn | 2156-7085 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/86571 | - |
dc.description.abstract | While high-speed intracoronary optical coherence tomography (OCT) provides three-dimensional (3D) visualization of coronary arteries in vivo, imaging speeds remain insufficient to avoid motion artifacts induced by heartbeat, limiting the clinical utility of OCT. In this paper, we demonstrate development of a high-speed intracoronary OCT system (frame rate: 500 frames/s, pullback speed: 100 mm/s) along with prospective electrocardiogram (ECG) triggering technology, which enabled volumetric imaging of long coronary segments within a single cardiac cycle (70 mm pullback in 0.7 s) with minimal cardiac motion artifact. This technology permitted detailed visualization of 3D architecture of the coronary arterial wall of a swine in vivo and fine structure of the implanted stent. (C) 2016 Optical Society of America | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | OPTICAL SOC AMER | - |
dc.subject | CORONARY-ARTERY MICROSCOPY | - |
dc.subject | FRACTIONAL FLOW RESERVE | - |
dc.subject | IMAGING IN-VIVO | - |
dc.subject | INTRAVASCULAR ULTRASOUND | - |
dc.subject | CLINICAL-APPLICATION | - |
dc.subject | HEARTBEAT OCT | - |
dc.subject | HIGH-SPEED | - |
dc.subject | ACQUISITION | - |
dc.subject | SCAFFOLDS | - |
dc.subject | 3D | - |
dc.title | Single cardiac cycle three-dimensional intracoronary optical coherence tomography | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Sunwon | - |
dc.contributor.affiliatedAuthor | Kim, Jin Won | - |
dc.identifier.doi | 10.1364/BOE.7.004847 | - |
dc.identifier.scopusid | 2-s2.0-85004187504 | - |
dc.identifier.wosid | 000390490700002 | - |
dc.identifier.bibliographicCitation | BIOMEDICAL OPTICS EXPRESS, v.7, no.12, pp.4847 - 4858 | - |
dc.relation.isPartOf | BIOMEDICAL OPTICS EXPRESS | - |
dc.citation.title | BIOMEDICAL OPTICS EXPRESS | - |
dc.citation.volume | 7 | - |
dc.citation.number | 12 | - |
dc.citation.startPage | 4847 | - |
dc.citation.endPage | 4858 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Biochemistry & Molecular Biology | - |
dc.relation.journalResearchArea | Optics | - |
dc.relation.journalResearchArea | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.relation.journalWebOfScienceCategory | Biochemical Research Methods | - |
dc.relation.journalWebOfScienceCategory | Optics | - |
dc.relation.journalWebOfScienceCategory | Radiology, Nuclear Medicine & Medical Imaging | - |
dc.subject.keywordPlus | CORONARY-ARTERY MICROSCOPY | - |
dc.subject.keywordPlus | FRACTIONAL FLOW RESERVE | - |
dc.subject.keywordPlus | IMAGING IN-VIVO | - |
dc.subject.keywordPlus | INTRAVASCULAR ULTRASOUND | - |
dc.subject.keywordPlus | CLINICAL-APPLICATION | - |
dc.subject.keywordPlus | HEARTBEAT OCT | - |
dc.subject.keywordPlus | HIGH-SPEED | - |
dc.subject.keywordPlus | ACQUISITION | - |
dc.subject.keywordPlus | SCAFFOLDS | - |
dc.subject.keywordPlus | 3D | - |
dc.subject.keywordAuthor | Endoscopic imaging | - |
dc.subject.keywordAuthor | Medical and biological imaging | - |
dc.subject.keywordAuthor | Optical coherence tomography | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
145 Anam-ro, Seongbuk-gu, Seoul, 02841, Korea+82-2-3290-2963
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.