Performance analysis of air source heat pump system for office building
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Han, Dongwon | - |
dc.contributor.author | Chang, Young Soo | - |
dc.contributor.author | Kim, Yongchan | - |
dc.date.accessioned | 2021-09-03T17:15:24Z | - |
dc.date.available | 2021-09-03T17:15:24Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2016-11 | - |
dc.identifier.issn | 1738-494X | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/86911 | - |
dc.description.abstract | In this study, the performance of an air source heat pump system installed in a commercial building is analyzed using the developed heat pump performance model and building load simulation data of several regions in Korea. The performance test of an air source heat pump system with a variable speed compressor is tested to develop model that considers changes in the performance characteristics of the heat pump system under various operating conditions. The heat pump system is installed in an environmental chamber, and the experimental equipment is set up according to the manufacturer's specifications as well as the AHRI 1230 test specifications. The performance test conditions of the heat pump system are selected using a central composite design method, in which 29 points for each cooling and heating mode are selected. The developed performance model based on experimental data predicts experimental values with an error of +/- 5 %. Building cooling and heating loads in three regions in Korea are analyzed using TRNSYS software, which includes standard building and weather data from Seoul, Daejeon and Busan in Korea. The effects of outdoor air temperature and part load ratio on the performance and regional monthly average power consumption of the heat pump system are analyzed. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | KOREAN SOC MECHANICAL ENGINEERS | - |
dc.subject | CONDITIONING SYSTEM | - |
dc.subject | ENERGY SIMULATION | - |
dc.subject | EFFICIENCY | - |
dc.title | Performance analysis of air source heat pump system for office building | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Yongchan | - |
dc.identifier.doi | 10.1007/s12206-016-1044-2 | - |
dc.identifier.scopusid | 2-s2.0-84994501734 | - |
dc.identifier.wosid | 000388131900047 | - |
dc.identifier.bibliographicCitation | JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, v.30, no.11, pp.5257 - 5268 | - |
dc.relation.isPartOf | JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY | - |
dc.citation.title | JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY | - |
dc.citation.volume | 30 | - |
dc.citation.number | 11 | - |
dc.citation.startPage | 5257 | - |
dc.citation.endPage | 5268 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.identifier.kciid | ART002163589 | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.description.journalRegisteredClass | kci | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalWebOfScienceCategory | Engineering, Mechanical | - |
dc.subject.keywordPlus | CONDITIONING SYSTEM | - |
dc.subject.keywordPlus | ENERGY SIMULATION | - |
dc.subject.keywordPlus | EFFICIENCY | - |
dc.subject.keywordAuthor | Heat pump | - |
dc.subject.keywordAuthor | Performance analysis | - |
dc.subject.keywordAuthor | Building load | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.