Implant Ball Attachment Fabricated with CAD/CAM to Overcome an Unfavorable Clinical Situation: A Case Report
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Shim, Ji Suk | - |
dc.contributor.author | Lim, Jae Hyung | - |
dc.contributor.author | Shin, Jung Hyun | - |
dc.contributor.author | Ryu, Jae Jun | - |
dc.contributor.author | Lee, Jeong Yol | - |
dc.contributor.author | Shin, Sang Wan | - |
dc.date.accessioned | 2021-09-03T17:41:55Z | - |
dc.date.available | 2021-09-03T17:41:55Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2016-11 | - |
dc.identifier.issn | 0893-2174 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/87049 | - |
dc.description.abstract | The most common complication of implant ball attachments is loss of retention via structural wear. Hence, parallel placement of implants was identified as a prerequisite for long-term success. In this case, although severe angulation was formed between implants due to severe alveolar bone resorption, parallel ball attachments on the implants could be fabricated using computer-aided design/computer-assisted manufacture. This procedure can be a solution when implants are placed with angulation and offers additional advantages such as long-term stability. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | QUINTESSENCE PUBLISHING CO INC | - |
dc.subject | OVERDENTURES | - |
dc.title | Implant Ball Attachment Fabricated with CAD/CAM to Overcome an Unfavorable Clinical Situation: A Case Report | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Shim, Ji Suk | - |
dc.contributor.affiliatedAuthor | Ryu, Jae Jun | - |
dc.contributor.affiliatedAuthor | Shin, Sang Wan | - |
dc.identifier.doi | 10.11607/ijp.4914 | - |
dc.identifier.scopusid | 2-s2.0-85007239563 | - |
dc.identifier.wosid | 000388550900015 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF PROSTHODONTICS, v.29, no.6, pp.611 - 613 | - |
dc.relation.isPartOf | INTERNATIONAL JOURNAL OF PROSTHODONTICS | - |
dc.citation.title | INTERNATIONAL JOURNAL OF PROSTHODONTICS | - |
dc.citation.volume | 29 | - |
dc.citation.number | 6 | - |
dc.citation.startPage | 611 | - |
dc.citation.endPage | 613 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
dc.subject.keywordPlus | OVERDENTURES | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
145 Anam-ro, Seongbuk-gu, Seoul, 02841, Korea+82-2-3290-2963
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.