Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A simple method for activating the platelets used in microfluidic platelet aggregation tests: Stirring-induced platelet activation

Authors
Lee, HoyoonKim, GyehyuLim, ChaeseungLee, ByoungKwonShin, Sehyun
Issue Date
11월-2016
Publisher
AMER INST PHYSICS
Citation
BIOMICROFLUIDICS, v.10, no.6
Indexed
SCIE
SCOPUS
Journal Title
BIOMICROFLUIDICS
Volume
10
Number
6
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/87072
DOI
10.1063/1.4972077
ISSN
1932-1058
Abstract
High-shear stimulation is well known as one of the key factors affecting platelet activation and aggregation, which can lead to the formation of a thrombus. In one of our previous studies, we introduced migration distance-based platelet function analysis in a microfluidic system. In this study, we set out to examine the effects of stirring on shearinduced platelet activation and aggregation in a chamber system by using a rotating stirrer. We found that the rotating stirrer caused not only rotational shear flow but also a strong radial secondary flow. The latter flow led to efficient mixing in the chamber. Moreover, the rotational flow led to the generation of shear stress, the magnitude of which can be controlled to activate the platelets. Activated platelets tend to aggregate themselves. The maximum platelet aggregation was observed at a critical shear rate of 3100 s(-1), regardless of the stirrer shape. Furthermore, the time taken to attain maximum aggregation was significantly shortened when using a wide stirrer (30 s) instead of a narrow one (180 s). When using a flat stirrer, the non-uniform shear field in the chamber system was resolved with the radial secondary flow-induced mixing; thus, most of the platelets were homogenously activated. The stirring-induced platelet activation mechanism was experimentally confirmed in a microfluidic system for a platelet aggregation test while monitoring the migration distance until the microfluidic channel is occluded. Our findings indicate that the present system, consisting of a rotating stirrer and a confined chamber, provides effective shear stimulation for activating platelets and inducing platelet aggregates. (C) 2016 Author(s).
Files in This Item
There are no files associated with this item.
Appears in
Collections
Graduate School > Department of Biomedical Sciences > 1. Journal Articles
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Lim, Chae Seung photo

Lim, Chae Seung
의과학과
Read more

Altmetrics

Total Views & Downloads

BROWSE