Influence of coil pitch on thermal performance of coil-type cast-in-place energy piles

Full metadata record
DC Field Value Language
dc.contributor.authorPark, Sangwoo-
dc.contributor.authorLee, Seokjae-
dc.contributor.authorLee, Dongseop-
dc.contributor.authorLee, Sean S.-
dc.contributor.authorChoi, Hangseok-
dc.date.accessioned2021-09-03T18:57:02Z-
dc.date.available2021-09-03T18:57:02Z-
dc.date.created2021-06-16-
dc.date.issued2016-10-01-
dc.identifier.issn0378-7788-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/87226-
dc.description.abstractRecently, the energy pile has been introduced as a viable alternative to the conventional closed-loop vertical ground heat exchanger (GHEX). The energy pile contains a heat exchange pipe inside the pile foundation and allows a circulation of working fluid through the pipe inducing heat exchange with the ground formation. In this paper, a series of thermal performance tests was conducted on two coil-type cast-in-place energy piles with different coil pitches, 200 mm and 500 mm, to evaluate the effect of coil pitch on the heat exchange performance of energy piles. Thermal performance tests were carried out by applying intermittent (8 h operating-16h pause) artificial cooling and heating loads with the aid of a constant-temperature water bath. The experimental result indicated that the heat exchange rate per pile length was not directly proportional to the installed pipe length because the tight coil pitch caused thermal interference between each pipe loop. In addition, a parametric study was conducted by computational fluid-dynamic (CFD) simulations to assess the effect of coil pitch and thermal interference on the thermal performance. The CFD model was verified by comparing the numerical simulation results with the field test data. Finally, an optimum coil pitch in the test bed condition was proposed considering the thermal performance and the economic feasibility of coil-type cast-in-place energy piles. (C) 2016 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE SA-
dc.titleInfluence of coil pitch on thermal performance of coil-type cast-in-place energy piles-
dc.typeArticle-
dc.contributor.affiliatedAuthorChoi, Hangseok-
dc.identifier.doi10.1016/j.enbuild.2016.08.005-
dc.identifier.scopusid2-s2.0-84984855503-
dc.identifier.wosid000383811100030-
dc.identifier.bibliographicCitationENERGY AND BUILDINGS, v.129, pp.344 - 356-
dc.relation.isPartOfENERGY AND BUILDINGS-
dc.citation.titleENERGY AND BUILDINGS-
dc.citation.volume129-
dc.citation.startPage344-
dc.citation.endPage356-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaConstruction & Building Technology-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalWebOfScienceCategoryConstruction & Building Technology-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEngineering, Civil-
dc.subject.keywordAuthorCast-in-place energy pile-
dc.subject.keywordAuthorThermal performance test-
dc.subject.keywordAuthorCoil-type ground heat exchanger-
dc.subject.keywordAuthorComputational fluid dynamic analysis-
dc.subject.keywordAuthorHeat exchange efficiency-
dc.subject.keywordAuthorOptimum coil pitch-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > School of Civil, Environmental and Architectural Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHOI, HANG SEOK photo

CHOI, HANG SEOK
공과대학 (건축사회환경공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE