Combined Positron Emission Tomography and Cerenkov Luminescence Imaging of Sentinel Lymph Nodes Using PEGylated Radionuclide-Embedded Gold Nanoparticles
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Sang Bong | - |
dc.contributor.author | Yoon, GhilSuk | - |
dc.contributor.author | Lee, Sang-Woo | - |
dc.contributor.author | Jeong, Shin Young | - |
dc.contributor.author | Ahn, Byeong-Cheol | - |
dc.contributor.author | Lim, Dong-Kwon | - |
dc.contributor.author | Lee, Jaetae | - |
dc.contributor.author | Jeon, Yong Hyun | - |
dc.date.accessioned | 2021-09-03T19:57:29Z | - |
dc.date.available | 2021-09-03T19:57:29Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2016-09-21 | - |
dc.identifier.issn | 1613-6810 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/87493 | - |
dc.description.abstract | New imaging probes with high sensitivity and stability are urgently needed to accurately detect sentinel lymph nodes (SLNs) for successful cancer diagnosis. Herein, the use of highly sensitive and stable PEGylated radionuclide-embedded gold nanoparticles (PEG-RIe-AuNPs) is reported for the detection of SLNs by combined positron emission tomography and Cerenkov luminescence imaging (PET/CLI). PEG-RIe-AuNPs show high sensitivity and stability both in vitro and in vivo, and are not toxic to normal ovarian and immune cells. In vivo PET/CLI imaging clearly reveals SLNs as early as 1 h post PEG-RIe-AuNP-injection, with peak signals achieved at 6 h postinjection, which is consistent with the biodistribution results. Taken together, the data provide strong evidence that PEG-RIe-AuNPs are promising as potential lymphatic tracers in biomedical imaging for pre and intraoperative surgical guidance. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY-V C H VERLAG GMBH | - |
dc.subject | QUANTUM DOTS | - |
dc.subject | BLUE-DYE | - |
dc.subject | CANCER | - |
dc.subject | EXPRESSION | - |
dc.subject | STABILITY | - |
dc.subject | NANOCAGES | - |
dc.subject | TRACKING | - |
dc.subject | LIGHT | - |
dc.title | Combined Positron Emission Tomography and Cerenkov Luminescence Imaging of Sentinel Lymph Nodes Using PEGylated Radionuclide-Embedded Gold Nanoparticles | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Lim, Dong-Kwon | - |
dc.identifier.doi | 10.1002/smll.201601721 | - |
dc.identifier.scopusid | 2-s2.0-84979018868 | - |
dc.identifier.wosid | 000383377700012 | - |
dc.identifier.bibliographicCitation | SMALL, v.12, no.35, pp.4894 - 4901 | - |
dc.relation.isPartOf | SMALL | - |
dc.citation.title | SMALL | - |
dc.citation.volume | 12 | - |
dc.citation.number | 35 | - |
dc.citation.startPage | 4894 | - |
dc.citation.endPage | 4901 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Chemistry | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalResearchArea | Materials Science | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Chemistry, Physical | - |
dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
dc.relation.journalWebOfScienceCategory | Materials Science, Multidisciplinary | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.relation.journalWebOfScienceCategory | Physics, Condensed Matter | - |
dc.subject.keywordPlus | QUANTUM DOTS | - |
dc.subject.keywordPlus | BLUE-DYE | - |
dc.subject.keywordPlus | CANCER | - |
dc.subject.keywordPlus | EXPRESSION | - |
dc.subject.keywordPlus | STABILITY | - |
dc.subject.keywordPlus | NANOCAGES | - |
dc.subject.keywordPlus | TRACKING | - |
dc.subject.keywordPlus | LIGHT | - |
dc.subject.keywordAuthor | cerenkov luminescence imaging | - |
dc.subject.keywordAuthor | gold nanoparticles | - |
dc.subject.keywordAuthor | positron emission tomography | - |
dc.subject.keywordAuthor | sentinel lymph node | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.