First-Order Mathematical Correlation Between Damping and Resonance Frequency Evaluating the Bone-Implant Interface
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kwon, Taek-Ka | - |
dc.contributor.author | Kim, Hae-Young | - |
dc.contributor.author | Yang, Jae-Ho | - |
dc.contributor.author | Wikesjo, Ulf M. E. | - |
dc.contributor.author | Lee, Jaebum | - |
dc.contributor.author | Koo, Ki-Tae | - |
dc.contributor.author | Yeo, In-Sung | - |
dc.date.accessioned | 2021-09-03T20:22:34Z | - |
dc.date.available | 2021-09-03T20:22:34Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2016-09 | - |
dc.identifier.issn | 0882-2786 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/87615 | - |
dc.description.abstract | Purpose: Various advanced technologies have been designed to estimate dental implant stability, including insertion torque, implant damping using the Periotest, and resonance frequency analysis expressed in implant stability quotient units. This study aimed to establish the relationship between the estimates for these three techniques. Materials and Methods: Bovine cortical bone blocks were trimmed to square shapes of precisely controlled thickness and density. Thereafter, 4-mm-diameter x 10-mm-long implants were placed in the bone blocks using 30-, 45-, and 60-Ncm insertion torques. Implant damping and resonance frequency analysis were conducted at four angles for each implant. Spearman correlation coefficients were calculated to examine the relationship between insertion torque, resonance frequency analysis, and implant damping measured values. Results: Resonance frequency analysis and implant damping estimates exhibited a strong inverse correlation (r = -0.98, P<.001). A linear equation was formulated: Periotest value = 15.54 + (-0.26 x implant stability quotient). Implant damping and resonance frequency estimates revealed a weak correlation with insertion torque (P<.05). Conclusion: This study mathematically defined a linear correlation between implant damping and resonance frequency estimates, thereby providing a guide for clinicians when deciding the loading time for dental implants using the implant damping or resonance frequency estimates. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | QUINTESSENCE PUBLISHING CO INC | - |
dc.subject | TITANIUM IMPLANTS | - |
dc.subject | STABILITY MEASUREMENTS | - |
dc.subject | INSERTION TORQUE | - |
dc.subject | LOADED IMPLANTS | - |
dc.subject | HUMAN CADAVER | - |
dc.subject | IN-VITRO | - |
dc.subject | MAXILLARY | - |
dc.subject | VALUES | - |
dc.subject | CAPACITY | - |
dc.subject | SYSTEMS | - |
dc.title | First-Order Mathematical Correlation Between Damping and Resonance Frequency Evaluating the Bone-Implant Interface | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Hae-Young | - |
dc.identifier.doi | 10.11607/jomi.4468 | - |
dc.identifier.scopusid | 2-s2.0-84998992745 | - |
dc.identifier.wosid | 000394447200006 | - |
dc.identifier.bibliographicCitation | INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, v.31, no.5, pp.1008 - 1015 | - |
dc.relation.isPartOf | INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS | - |
dc.citation.title | INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS | - |
dc.citation.volume | 31 | - |
dc.citation.number | 5 | - |
dc.citation.startPage | 1008 | - |
dc.citation.endPage | 1015 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
dc.subject.keywordPlus | TITANIUM IMPLANTS | - |
dc.subject.keywordPlus | STABILITY MEASUREMENTS | - |
dc.subject.keywordPlus | INSERTION TORQUE | - |
dc.subject.keywordPlus | LOADED IMPLANTS | - |
dc.subject.keywordPlus | HUMAN CADAVER | - |
dc.subject.keywordPlus | IN-VITRO | - |
dc.subject.keywordPlus | MAXILLARY | - |
dc.subject.keywordPlus | VALUES | - |
dc.subject.keywordPlus | CAPACITY | - |
dc.subject.keywordPlus | SYSTEMS | - |
dc.subject.keywordAuthor | damping | - |
dc.subject.keywordAuthor | implant stability | - |
dc.subject.keywordAuthor | insertion torque | - |
dc.subject.keywordAuthor | Periotest | - |
dc.subject.keywordAuthor | resonance frequency analysis | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.