Nu and Sh correlations for LiCl solution and moist air in plate type dehumidifier

Authors
Lee, Jae HyunJung, Chung WooChang, Young SooChung, Jin TaekKang, Yong Tae
Issue Date
9월-2016
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Keywords
Dehumidification effectiveness; Lithium chloride; Liquid desiccant; Plate type dehumidifier
Citation
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, v.100, pp.433 - 444
Indexed
SCIE
SCOPUS
Journal Title
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER
Volume
100
Start Page
433
End Page
444
URI
https://scholar.korea.ac.kr/handle/2021.sw.korea/87762
DOI
10.1016/j.ijheatmasstransfer.2016.04.100
ISSN
0017-9310
Abstract
To cope with environmental pollution caused by rapid industrial development, international regulations such as the Montreal Protocol and the United Nations Framework Convention on Climate Change are becoming materialized day by day. As a result, interest in energy saving devices is increasing and studies are being concentrated on highly efficient refrigeration air conditioning systems. In this study, a desiccant cooling technology using a liquid desiccant of LiCl solution was researched. The plate was treated with hydrophilic coating and the wettability was improved by giving a groove shape. Consequently, a thin liquid film was maintained even with a small amount of desiccant solution, thereby increasing the stability of the liquid film and solving the scattering problem of the desiccant solution. In this study, it is found that the absorption rate increases with the increases of the liquid desiccant and air velocity and the air velocity has more significant effect on the absorption rate than the liquid desiccant solution flow. It is found that the absorption rate becomes higher with increasing the higher relative humidity and the concentration of liquid desiccant. The dehumidification effectiveness decreases greatly as the air velocity increases. Furthermore, it is concluded that the air velocity has the greatest effect on the improvement of the absorption rate and heat and mass transfer. In this experiment, Sh and Nu correlations of the air side and desiccant solution side with an error of 25% were developed, respectively, and the absorption rate, dehumidification effectiveness and the experimental correlations were compared with other studies. (C) 2016 Elsevier Ltd. All rights reserved.
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Kang, Yong Tae photo

Kang, Yong Tae
공과대학 (기계공학부)
Read more

Altmetrics

Total Views & Downloads

BROWSE