Optimal meter placement for pipe burst detection in water distribution systems
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Hagos, Medhanie | - |
dc.contributor.author | Jung, Donghwi | - |
dc.contributor.author | Lansey, Kevin E. | - |
dc.date.accessioned | 2021-09-03T22:18:29Z | - |
dc.date.available | 2021-09-03T22:18:29Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2016-07 | - |
dc.identifier.issn | 1464-7141 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/88157 | - |
dc.description.abstract | Pipe bursts in water distribution systems (WDS) must be rapidly detected to minimize the loss of system functionality and recovery time. Pipe burst is the most common failure in WDS. It results in water loss out of the system, increased head losses, and low pressure at the customers' taps. Therefore, effective and efficient detection of pipe bursts can improve system resilience. To this end, this study proposes an optimal meter placement model to identify meter locations that maximize detection effectiveness for a given number of meters and type of meter. The linear programming model is demonstrated on a modified Austin EPANET hydraulic network. Receiver operating characteristic (ROC) curves for alternative pressure and flow meters are applied to investigate the relationship between the level of available information and pipe burst detection effectiveness. The optimal sensor locations were distinctly different depending on the type of meter and the objective to be considered. The ROC curves for alternative pressure and pipe flow meters showed that pipe flow meters are vulnerable to false alarms, and that using many pipe flow meters could detect all pipe bursts. Pressure meters could detect up to 82% of the burst events. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IWA PUBLISHING | - |
dc.subject | METHODOLOGY | - |
dc.title | Optimal meter placement for pipe burst detection in water distribution systems | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Jung, Donghwi | - |
dc.identifier.doi | 10.2166/hydro.2016.170 | - |
dc.identifier.scopusid | 2-s2.0-84976463178 | - |
dc.identifier.wosid | 000379214900009 | - |
dc.identifier.bibliographicCitation | JOURNAL OF HYDROINFORMATICS, v.18, no.4, pp.741 - 756 | - |
dc.relation.isPartOf | JOURNAL OF HYDROINFORMATICS | - |
dc.citation.title | JOURNAL OF HYDROINFORMATICS | - |
dc.citation.volume | 18 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 741 | - |
dc.citation.endPage | 756 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Computer Science | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Environmental Sciences & Ecology | - |
dc.relation.journalResearchArea | Water Resources | - |
dc.relation.journalWebOfScienceCategory | Computer Science, Interdisciplinary Applications | - |
dc.relation.journalWebOfScienceCategory | Engineering, Civil | - |
dc.relation.journalWebOfScienceCategory | Environmental Sciences | - |
dc.relation.journalWebOfScienceCategory | Water Resources | - |
dc.subject.keywordPlus | METHODOLOGY | - |
dc.subject.keywordAuthor | detection | - |
dc.subject.keywordAuthor | pipe bursts | - |
dc.subject.keywordAuthor | receiver operating characteristic (ROC) | - |
dc.subject.keywordAuthor | water distribution system | - |
dc.subject.keywordAuthor | Western Electric Company (WEC) rules | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.