Effect of 5 MeV proton irradiation damage on performance of beta-Ga2O3 photodetectors
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Ahn, Shihyun | - |
dc.contributor.author | Lin, Yi-Hsuan | - |
dc.contributor.author | Ren, Fan | - |
dc.contributor.author | Oh, Sooyeoun | - |
dc.contributor.author | Jung, Younghun | - |
dc.contributor.author | Yang, Gwangseok | - |
dc.contributor.author | Kim, Jihyun | - |
dc.contributor.author | Mastro, Michael A. | - |
dc.contributor.author | Hite, Jennifer K. | - |
dc.contributor.author | Eddy, Charles R., Jr. | - |
dc.contributor.author | Pearton, Stephen J. | - |
dc.date.accessioned | 2021-09-03T22:22:51Z | - |
dc.date.available | 2021-09-03T22:22:51Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2016-07 | - |
dc.identifier.issn | 1071-1023 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/88190 | - |
dc.description.abstract | Planar thin film beta-Ga2O3 photodetectors were irradiated with 5 MeV protons at doses from 10(13) to 10(15) cm(-2), and the resulting effects on photocurrent, responsivity, quantum efficiency, and photo-to-dark current ratio at 254 nm wavelength were measured at both 25 and 150 degrees C. The photocurrent increased with dose due to the introduction of damage from nonionizing energy loss by the protons. The total calculated vacancy concentration increased from 5 x 10(15) to 5 x 10(17) cm(-3) over the dose range investigated. The dark current increased in proportion with the implant dose, leading to a decrease in the ratio of photocurrent to dark current. The photocurrent induced by 254 nm illumination increased with dose, from similar to 0.3 x 10(-7) A at 25 degrees C for a dose of 10(13) cm(-2) to similar to 10(-6) A at a dose of 10(15) cm(-2) at a fixed light intensity of 760 mu W/cm(2). The phototo- dark current ratio decreased from similar to 60 in the control samples to similar to 9 after proton doses of 10(15) cm(-2), with corresponding external quantum efficiencies of similar to 10(3) % in control samples, similar to 2 x 10(3) % for a dose of 10(13) cm(-2), and 10 4 % for a dose of 10(15) cm(-2). The mechanism for the increase in photocurrent is the introduction of gap states, since the dark current of the photodetectors was increased by illuminating with sub-bandgap (red or green laser light) for the proton irradiated samples. (C) 2016 American Vacuum Society. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | A V S AMER INST PHYSICS | - |
dc.subject | SOLAR-BLIND PHOTODETECTORS | - |
dc.subject | GALLIUM OXIDE-FILMS | - |
dc.subject | THIN-FILMS | - |
dc.title | Effect of 5 MeV proton irradiation damage on performance of beta-Ga2O3 photodetectors | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Jihyun | - |
dc.identifier.doi | 10.1116/1.4950872 | - |
dc.identifier.scopusid | 2-s2.0-84971499029 | - |
dc.identifier.wosid | 000382207700024 | - |
dc.identifier.bibliographicCitation | JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, v.34, no.4 | - |
dc.relation.isPartOf | JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B | - |
dc.citation.title | JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B | - |
dc.citation.volume | 34 | - |
dc.citation.number | 4 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Science & Technology - Other Topics | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Nanoscience & Nanotechnology | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordPlus | SOLAR-BLIND PHOTODETECTORS | - |
dc.subject.keywordPlus | GALLIUM OXIDE-FILMS | - |
dc.subject.keywordPlus | THIN-FILMS | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.