Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Performance investigation on solid desiccant assisted mobile air conditioning system

Full metadata record
DC Field Value Language
dc.contributor.authorLee, Hoseong-
dc.contributor.authorLin, Xiaojie-
dc.contributor.authorHwang, Yunho-
dc.contributor.authorRadermacher, Reinhard-
dc.date.accessioned2021-09-03T22:41:33Z-
dc.date.available2021-09-03T22:41:33Z-
dc.date.created2021-06-18-
dc.date.issued2016-06-25-
dc.identifier.issn1359-4311-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/88304-
dc.description.abstractIn the conventional mobile air conditioning system, the temperature and humidity control is achieved by a vapor compression system. This system cools the air down to lower than the dew point temperate of the cabin to control the humidity. Thus, reheating of the air is necessary. These two factors could increase the fuel consumption of the system. To overcome these issues, a solid desiccant assisted mobile air conditioning system is proposed and investigated. The desiccant assisted technology can separate the latent heat load from the sensible heat load, which will effectively increase the evaporating temperature and reduce the power consumption of the compressor. It is proposed to apply the solid desiccant to the mobile air conditioning system to handle most of latent load, while the vapor compression cycle handles the remaining latent load and sensible load. The model of the proposed concept is developed and validated with experimental data. Lastly, the possible configurations of the solid desiccant assisted mobile air conditioning system are discussed. (C) 2016 Elsevier Ltd. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherPERGAMON-ELSEVIER SCIENCE LTD-
dc.subjectHEAT-TRANSFER-
dc.titlePerformance investigation on solid desiccant assisted mobile air conditioning system-
dc.typeArticle-
dc.contributor.affiliatedAuthorLee, Hoseong-
dc.identifier.doi10.1016/j.applthermaleng.2016.05.053-
dc.identifier.scopusid2-s2.0-84966300019-
dc.identifier.wosid000379560500137-
dc.identifier.bibliographicCitationAPPLIED THERMAL ENGINEERING, v.103, pp.1370 - 1380-
dc.relation.isPartOfAPPLIED THERMAL ENGINEERING-
dc.citation.titleAPPLIED THERMAL ENGINEERING-
dc.citation.volume103-
dc.citation.startPage1370-
dc.citation.endPage1380-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaThermodynamics-
dc.relation.journalResearchAreaEnergy & Fuels-
dc.relation.journalResearchAreaEngineering-
dc.relation.journalResearchAreaMechanics-
dc.relation.journalWebOfScienceCategoryThermodynamics-
dc.relation.journalWebOfScienceCategoryEnergy & Fuels-
dc.relation.journalWebOfScienceCategoryEngineering, Mechanical-
dc.relation.journalWebOfScienceCategoryMechanics-
dc.subject.keywordPlusHEAT-TRANSFER-
dc.subject.keywordAuthorMobile air conditioning system-
dc.subject.keywordAuthorSolid desiccant-
dc.subject.keywordAuthorSeparate sensible and latent cooling-
dc.subject.keywordAuthorSSLC-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Engineering > Department of Mechanical Engineering > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE