Optimization-Based Reconfiguration Method for Power System Incorporating Superconducting Fault Current Limiter Failure
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kong, Seongbae | - |
dc.contributor.author | Jo, Hyung-Chul | - |
dc.contributor.author | Wi, Young-Min | - |
dc.contributor.author | Joo, Sung-Kwan | - |
dc.date.accessioned | 2021-09-03T23:26:33Z | - |
dc.date.available | 2021-09-03T23:26:33Z | - |
dc.date.created | 2021-06-18 | - |
dc.date.issued | 2016-06 | - |
dc.identifier.issn | 1051-8223 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/88527 | - |
dc.description.abstract | Superconducting fault current limiters (SFCLs) are increasingly being used as a mechanism to effectively control fault currents in a power system. However, SFCL placement and relay coordination can be complicated by the unexpected failure or maintenance of SFCLs. This paper presents a power system reconfiguration method for coordinating overcurrent protection considering SFCL failure in system protection. The proposed power system reconfiguration method is designed to handle SFCL failure in the relay coordination. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC | - |
dc.title | Optimization-Based Reconfiguration Method for Power System Incorporating Superconducting Fault Current Limiter Failure | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Joo, Sung-Kwan | - |
dc.identifier.doi | 10.1109/TASC.2016.2547882 | - |
dc.identifier.scopusid | 2-s2.0-84964262417 | - |
dc.identifier.wosid | 000375080300001 | - |
dc.identifier.bibliographicCitation | IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, v.26, no.4 | - |
dc.relation.isPartOf | IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY | - |
dc.citation.title | IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY | - |
dc.citation.volume | 26 | - |
dc.citation.number | 4 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Engineering | - |
dc.relation.journalResearchArea | Physics | - |
dc.relation.journalWebOfScienceCategory | Engineering, Electrical & Electronic | - |
dc.relation.journalWebOfScienceCategory | Physics, Applied | - |
dc.subject.keywordAuthor | Distributed generation (DG) | - |
dc.subject.keywordAuthor | fault current | - |
dc.subject.keywordAuthor | relay coordination | - |
dc.subject.keywordAuthor | superconducting fault current limiter (SFCL) | - |
dc.subject.keywordAuthor | system reconfiguration | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
145 Anam-ro, Seongbuk-gu, Seoul, 02841, Korea+82-2-3290-2963
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.