Impact of positional changes in neural monitoring endotracheal tube on amplitude and latency of electromyographic response in monitored thyroid surgery: Results from the Porcine Experiment
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Hoon Yub | - |
dc.contributor.author | Tufano, Ralph P. | - |
dc.contributor.author | Randolph, Gregory | - |
dc.contributor.author | Barczynski, Marcin | - |
dc.contributor.author | Wu, Che-Wei | - |
dc.contributor.author | Chiang, Feng-Yu | - |
dc.contributor.author | Liu, Xiaoli | - |
dc.contributor.author | Masuoka, Hiroo | - |
dc.contributor.author | Miyauchi, Akira | - |
dc.contributor.author | Park, Soo Young | - |
dc.contributor.author | Kwak, Hee Yong | - |
dc.contributor.author | Lee, Hye Yoon | - |
dc.contributor.author | Dionigi, Gianlorenzo | - |
dc.date.accessioned | 2021-09-04T00:55:53Z | - |
dc.date.available | 2021-09-04T00:55:53Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2016-04 | - |
dc.identifier.issn | 1043-3074 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/89002 | - |
dc.description.abstract | Background. The purpose of this study was to evaluate electromyography (EMG) amplitude and latency changes during tube dislocation in monitored thyroid surgery, which may be observed without recurrent laryngeal nerve injury. Methods. Duroc-Landrace piglets were intubated with the TriVantage EMG tube. We measured EMG changes during both upward and downward tube dislocation (10-20 mm) and rotation (45-90 degrees) with continuous neuromonitoring. Results. The EMG amplitude varied significantly with induced endotracheal tube rotation and depth changes. However, the EMG latency was relatively unaffected by such tube dislocation, just a transient artifactual latency change was observed in the situation of extreme amplitude variation. Conclusion. Amplitude changes without latency changes may be due to changes in tube position alone during surgery, but could still reflect a neurophysiologic event; amplitude changes during neuropraxic injury merit additional investigation. Thus, the combined event (concordant amplitude decrease and latency increase) serves as an appropriate adverse EMG event correlating with impending neural injury. (c) 2015 Wiley Periodicals, Inc. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY | - |
dc.subject | RECURRENT LARYNGEAL NERVE | - |
dc.subject | INJURY | - |
dc.subject | STIMULATION | - |
dc.subject | PLACEMENT | - |
dc.title | Impact of positional changes in neural monitoring endotracheal tube on amplitude and latency of electromyographic response in monitored thyroid surgery: Results from the Porcine Experiment | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Hoon Yub | - |
dc.identifier.doi | 10.1002/hed.24145 | - |
dc.identifier.scopusid | 2-s2.0-84937139585 | - |
dc.identifier.wosid | 000375116400125 | - |
dc.identifier.bibliographicCitation | HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, v.38, pp.E1004 - E1008 | - |
dc.relation.isPartOf | HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK | - |
dc.citation.title | HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK | - |
dc.citation.volume | 38 | - |
dc.citation.startPage | E1004 | - |
dc.citation.endPage | E1008 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Otorhinolaryngology | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Otorhinolaryngology | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | RECURRENT LARYNGEAL NERVE | - |
dc.subject.keywordPlus | INJURY | - |
dc.subject.keywordPlus | STIMULATION | - |
dc.subject.keywordPlus | PLACEMENT | - |
dc.subject.keywordAuthor | thyroid | - |
dc.subject.keywordAuthor | recurrent laryngeal nerve | - |
dc.subject.keywordAuthor | amplitude | - |
dc.subject.keywordAuthor | latency | - |
dc.subject.keywordAuthor | electromyography | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.