APPROACH FOR NEEDLE INSERTION INTO THE TIBIALIS POSTERIOR: AN ULTRASONOGRAPHY STUDY
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Won, Sun Jae | - |
dc.contributor.author | Yoon, Joon Shik | - |
dc.date.accessioned | 2021-09-04T00:56:09Z | - |
dc.date.available | 2021-09-04T00:56:09Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2016-04 | - |
dc.identifier.issn | 0148-639X | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/89004 | - |
dc.description.abstract | Introduction: To avoid neurovascular damage by needle electrode insertion into the tibialis posterior, we used ultrasonography to determine the proper insertion point based on anatomic landmarks. Methods: Using ultrasonography, the safety window, the corrected safety window, and the depth of the tibialis posterior were measured at 4 points (the upper third and midpoint of the tibia using anterior and posterior approaches) in healthy volunteers. Results: The safety window at the midpoint for the posterior approach was significantly larger than at the other points. The corrected safety window could be defined only at the upper third for the anterior approach and at the midpoint for the posterior approach. Conclusions: Among the 4 points used for needle insertion into the tibialis posterior, the midpoint by the posterior approach may be the most favorable insertion point. The upper third may be better for the anterior approach. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | WILEY-BLACKWELL | - |
dc.subject | ELECTRODE INSERTION | - |
dc.subject | MUSCLE | - |
dc.subject | LOCALIZATION | - |
dc.subject | INJECTIONS | - |
dc.subject | LOCATION | - |
dc.subject | ANTERIOR | - |
dc.title | APPROACH FOR NEEDLE INSERTION INTO THE TIBIALIS POSTERIOR: AN ULTRASONOGRAPHY STUDY | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Yoon, Joon Shik | - |
dc.identifier.doi | 10.1002/mus.24794 | - |
dc.identifier.scopusid | 2-s2.0-84961128589 | - |
dc.identifier.wosid | 000373348300006 | - |
dc.identifier.bibliographicCitation | MUSCLE & NERVE, v.53, no.4, pp.528 - 531 | - |
dc.relation.isPartOf | MUSCLE & NERVE | - |
dc.citation.title | MUSCLE & NERVE | - |
dc.citation.volume | 53 | - |
dc.citation.number | 4 | - |
dc.citation.startPage | 528 | - |
dc.citation.endPage | 531 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Neurosciences & Neurology | - |
dc.relation.journalWebOfScienceCategory | Clinical Neurology | - |
dc.relation.journalWebOfScienceCategory | Neurosciences | - |
dc.subject.keywordPlus | ELECTRODE INSERTION | - |
dc.subject.keywordPlus | MUSCLE | - |
dc.subject.keywordPlus | LOCALIZATION | - |
dc.subject.keywordPlus | INJECTIONS | - |
dc.subject.keywordPlus | LOCATION | - |
dc.subject.keywordPlus | ANTERIOR | - |
dc.subject.keywordAuthor | anterior approach | - |
dc.subject.keywordAuthor | electromyography | - |
dc.subject.keywordAuthor | posterior approach | - |
dc.subject.keywordAuthor | tibialis posterior | - |
dc.subject.keywordAuthor | ultrasonography | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.