New approach to accuracy verification of 3D surface models: An analysis of point cloud coordinates
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Lee, Wan-Sun | - |
dc.contributor.author | Park, Jong-Kyoung | - |
dc.contributor.author | Kim, Ji-Hwan | - |
dc.contributor.author | Kim, Hae-Young | - |
dc.contributor.author | Kim, Woong-Chul | - |
dc.contributor.author | Yu, Chin-Ho | - |
dc.date.accessioned | 2021-09-04T01:03:13Z | - |
dc.date.available | 2021-09-04T01:03:13Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2016-04 | - |
dc.identifier.issn | 1883-1958 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/89055 | - |
dc.description.abstract | Purpose: The precision of two types of surface digitization devices, i.e., a contact probe scanner and an optical scanner, and the trueness of two types of stone replicas, i.e., one without an imaging powder (SR/NP) and one with an imaging powder (SR/P), were evaluated using a computer-aided analysis. Methods: A master die was fabricated from stainless steel. Ten impressions were taken, and ten stone replicas were prepared from Type IV stone (Fujirock EP, GC, Leuven, Belgium). The precision of two types of scanners was analyzed using the root mean square (RMS), measurement error (ME), and limits of agreement (LoA) at each coordinate. The trueness of the stone replicas was evaluated using the total deviation. A Student's t-test was applied to compare the discrepancies between the CAD-reference-models of the master die (m-CRM) and point clouds for the two types of stone replicas (alpha = .05). Results: The RMS values for the precision were 1.58, 1.28, and 0.98 mm along the x-, y-, and z-axes in the contact probe scanner and 1.97, 1.32, and 1.33 mm along the x-, y-, and z-axes in the optical scanner, respectively. A comparison with m-CRM revealed a trueness of 7.10 mu m for SR/NP and 8.65 mu m for SR/P. Conclusions: The precision at each coordinate (x-, y-, and z-axes) was revealed to be higher than the one assessed in the previous method (overall offset differences). A comparison between the m-CRM and 3D surface models of the stone replicas revealed a greater dimensional change in SR/P than in SR/NP. (C) 2015 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER IRELAND LTD | - |
dc.subject | DENTAL CAD/CAM TECHNOLOGY | - |
dc.subject | COMPUTER-AIDED ANALYSIS | - |
dc.subject | CROWNS IN-VITRO | - |
dc.subject | 3-DIMENSIONAL FIT | - |
dc.subject | IMPRESSIONS | - |
dc.subject | DIGITIZATION | - |
dc.subject | SCANNER | - |
dc.title | New approach to accuracy verification of 3D surface models: An analysis of point cloud coordinates | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Ji-Hwan | - |
dc.contributor.affiliatedAuthor | Kim, Hae-Young | - |
dc.contributor.affiliatedAuthor | Kim, Woong-Chul | - |
dc.identifier.doi | 10.1016/j.jpor.2015.10.002 | - |
dc.identifier.scopusid | 2-s2.0-84947304842 | - |
dc.identifier.wosid | 000375037900005 | - |
dc.identifier.bibliographicCitation | JOURNAL OF PROSTHODONTIC RESEARCH, v.60, no.2, pp.98 - 105 | - |
dc.relation.isPartOf | JOURNAL OF PROSTHODONTIC RESEARCH | - |
dc.citation.title | JOURNAL OF PROSTHODONTIC RESEARCH | - |
dc.citation.volume | 60 | - |
dc.citation.number | 2 | - |
dc.citation.startPage | 98 | - |
dc.citation.endPage | 105 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Dentistry, Oral Surgery & Medicine | - |
dc.relation.journalWebOfScienceCategory | Dentistry, Oral Surgery & Medicine | - |
dc.subject.keywordPlus | DENTAL CAD/CAM TECHNOLOGY | - |
dc.subject.keywordPlus | COMPUTER-AIDED ANALYSIS | - |
dc.subject.keywordPlus | CROWNS IN-VITRO | - |
dc.subject.keywordPlus | 3-DIMENSIONAL FIT | - |
dc.subject.keywordPlus | IMPRESSIONS | - |
dc.subject.keywordPlus | DIGITIZATION | - |
dc.subject.keywordPlus | SCANNER | - |
dc.subject.keywordAuthor | 3D surface model | - |
dc.subject.keywordAuthor | Point cloud | - |
dc.subject.keywordAuthor | Precision | - |
dc.subject.keywordAuthor | Trueness | - |
dc.subject.keywordAuthor | Accuracy | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.