Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

Evaluation of radiation doses in patient and medical staff during endoscopic retrograde cholangiopancreatography procedures

Full metadata record
DC Field Value Language
dc.contributor.authorSeo, Deoknam-
dc.contributor.authorKim, Kie Hwan-
dc.contributor.authorKim, Jung-Su-
dc.contributor.authorHan, Seonggyu-
dc.contributor.authorPark, Kyung-
dc.contributor.authorKim, Jungmin-
dc.date.accessioned2021-09-04T02:09:06Z-
dc.date.available2021-09-04T02:09:06Z-
dc.date.created2021-06-16-
dc.date.issued2016-03-
dc.identifier.issn0144-8420-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/89350-
dc.description.abstractThe radiation exposure dose must be optimised because the hazard resulting from an interventional radiology procedure is long term depending on the patient. The aim of this study was to measure the radiation doses received by the patients and medical staff during endoscopic retrograde cholangiopancreatography (ERCP) procedures. Data were collected during 126 ERCP procedures, including the dose-area product (DAP), entrance dose (ED), effective dose (E), fluoroscopy time (T) and number of digital radiographs (F). The medical staff members each wore a personal thermoluminescence dosemeter to monitor exposure during ERCP procedures. The mean DAP, ED, E and T were 47.06 Gy cm(2), 196.06 mGy, 8.93 mSv, 7.65 min and 9.21 images, respectively. The mean dose to the staff was 0.175 mSv and that to the assistant was 0.069 mSv. The dose to the medical staff was minimal when appropriate protective measures were used. The large variation in the patient doses must be further investigated.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherOXFORD UNIV PRESS-
dc.subjectEXPOSURE-
dc.subjectREDUCTION-
dc.subjectPERSONNEL-
dc.subjectERCP-
dc.subjectSKIN-
dc.titleEvaluation of radiation doses in patient and medical staff during endoscopic retrograde cholangiopancreatography procedures-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Jungmin-
dc.identifier.doi10.1093/rpd/ncv373-
dc.identifier.scopusid2-s2.0-84959905342-
dc.identifier.wosid000371608500011-
dc.identifier.bibliographicCitationRADIATION PROTECTION DOSIMETRY, v.168, no.4, pp.516 - 522-
dc.relation.isPartOfRADIATION PROTECTION DOSIMETRY-
dc.citation.titleRADIATION PROTECTION DOSIMETRY-
dc.citation.volume168-
dc.citation.number4-
dc.citation.startPage516-
dc.citation.endPage522-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaEnvironmental Sciences & Ecology-
dc.relation.journalResearchAreaPublic, Environmental & Occupational Health-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaRadiology, Nuclear Medicine & Medical Imaging-
dc.relation.journalWebOfScienceCategoryEnvironmental Sciences-
dc.relation.journalWebOfScienceCategoryPublic, Environmental & Occupational Health-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryRadiology, Nuclear Medicine & Medical Imaging-
dc.subject.keywordPlusEXPOSURE-
dc.subject.keywordPlusREDUCTION-
dc.subject.keywordPlusPERSONNEL-
dc.subject.keywordPlusERCP-
dc.subject.keywordPlusSKIN-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Health Sciences > School of Health and Environmental Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Altmetrics

Total Views & Downloads

BROWSE