Spectral analysis of intracranial pressure: Is it helpful in the assessment of shunt functioning in-vivo?
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Kim, Dong-Joo | - |
dc.contributor.author | Kim, Hakseung | - |
dc.contributor.author | Jeong, Eun-Jin | - |
dc.contributor.author | Lee, Hack-Jin | - |
dc.contributor.author | Czosnyka, Marek | - |
dc.contributor.author | Son, Yunsik | - |
dc.contributor.author | Kim, Byung-Jo | - |
dc.contributor.author | Czosnyka, Zofia | - |
dc.date.accessioned | 2021-09-04T02:19:16Z | - |
dc.date.available | 2021-09-04T02:19:16Z | - |
dc.date.created | 2021-06-16 | - |
dc.date.issued | 2016-03 | - |
dc.identifier.issn | 0303-8467 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/89428 | - |
dc.description.abstract | Objective: Shunt failure is common in hydrocephalic patients. The cerebrospinal fluid (CSF) infusion test enables the assessment of CSF absorption capacity, which is represented by the resistance to CSF outflow (R-OUT) However, shunt failure may not only affect the CSF absorption capacity but also the intracranial compliance or compensatory properties. Spectral analysis of the ICP signal obtained during the infusion test may enable the comprehensive assessment of the overall deterioration caused by shunt failure. Material and methods: A total of 121 hydrocephalic shunted patients underwent the infusion test with continuous intracranial pressure (ICP) and arterial blood pressure (ABP) recording. The maximum amplitudes of three major frequency bandwidths (0.2-2.6, 2.6-4.0 and 4.0-15 Hz, respectively) were calculated from the ICP. Statistical analyses were conducted to identify factors significantly associated with shunt failure, to construct an index (i.e., the shunt response parameter, SRP) for detecting shunt failure, and to define thresholds for R-OUT and SRP. Results: The R-OUT threshold for detecting shunt failure was 7.59 mmHg/ml/min, and this threshold showed an accuracy of 82.64%. All spectral parameters were found to be significantly associated with shunt patency (p < 0.05). The SRP exhibited significantly better accuracy than Ran in detecting shunt failure (91.74%). Conclusion: The hydrodynamic assessment of shunted patients enhanced by spectral analysis during the infusion test detected shunt failure with high accuracy. Although further validation is needed, the SRP exhibited promising results. (C) 2016 Elsevier B.V. All rights reserved. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | ELSEVIER SCIENCE BV | - |
dc.subject | FLUID OUTFLOW RESISTANCE | - |
dc.subject | CEREBROSPINAL-FLUID | - |
dc.subject | CSF OUTFLOW | - |
dc.subject | PULSE-WAVE | - |
dc.subject | LONG-TERM | - |
dc.subject | HYDROCEPHALUS | - |
dc.subject | FAILURE | - |
dc.subject | SYSTEM | - |
dc.subject | CONDUCTANCE | - |
dc.subject | INFUSION | - |
dc.title | Spectral analysis of intracranial pressure: Is it helpful in the assessment of shunt functioning in-vivo? | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | Kim, Dong-Joo | - |
dc.contributor.affiliatedAuthor | Kim, Hakseung | - |
dc.contributor.affiliatedAuthor | Son, Yunsik | - |
dc.contributor.affiliatedAuthor | Kim, Byung-Jo | - |
dc.identifier.doi | 10.1016/j.clineuro.2016.01.023 | - |
dc.identifier.scopusid | 2-s2.0-84956609187 | - |
dc.identifier.wosid | 000372677400019 | - |
dc.identifier.bibliographicCitation | CLINICAL NEUROLOGY AND NEUROSURGERY, v.142, pp.112 - 119 | - |
dc.relation.isPartOf | CLINICAL NEUROLOGY AND NEUROSURGERY | - |
dc.citation.title | CLINICAL NEUROLOGY AND NEUROSURGERY | - |
dc.citation.volume | 142 | - |
dc.citation.startPage | 112 | - |
dc.citation.endPage | 119 | - |
dc.type.rims | ART | - |
dc.type.docType | Article | - |
dc.description.journalClass | 1 | - |
dc.description.journalRegisteredClass | scie | - |
dc.description.journalRegisteredClass | scopus | - |
dc.relation.journalResearchArea | Neurosciences & Neurology | - |
dc.relation.journalResearchArea | Surgery | - |
dc.relation.journalWebOfScienceCategory | Clinical Neurology | - |
dc.relation.journalWebOfScienceCategory | Surgery | - |
dc.subject.keywordPlus | FLUID OUTFLOW RESISTANCE | - |
dc.subject.keywordPlus | CEREBROSPINAL-FLUID | - |
dc.subject.keywordPlus | CSF OUTFLOW | - |
dc.subject.keywordPlus | PULSE-WAVE | - |
dc.subject.keywordPlus | LONG-TERM | - |
dc.subject.keywordPlus | HYDROCEPHALUS | - |
dc.subject.keywordPlus | FAILURE | - |
dc.subject.keywordPlus | SYSTEM | - |
dc.subject.keywordPlus | CONDUCTANCE | - |
dc.subject.keywordPlus | INFUSION | - |
dc.subject.keywordAuthor | Cerebrospinal fluid | - |
dc.subject.keywordAuthor | Shunt | - |
dc.subject.keywordAuthor | Hydrocephalus | - |
dc.subject.keywordAuthor | Waveform analysis | - |
dc.subject.keywordAuthor | Infusion test | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
145 Anam-ro, Seongbuk-gu, Seoul, 02841, Korea+82-2-3290-2963
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.