Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

The small-angle performance of a dual-readout fiber calorimeter

Full metadata record
DC Field Value Language
dc.contributor.authorCardini, A.-
dc.contributor.authorCascella, M.-
dc.contributor.authorChoi, S.-
dc.contributor.authorDe Pedis, D.-
dc.contributor.authorFerrari, R.-
dc.contributor.authorFranchino, S.-
dc.contributor.authorGaudio, G.-
dc.contributor.authorHa, S.-
dc.contributor.authorHauptman, J.-
dc.contributor.authorLa Rotonda, L.-
dc.contributor.authorLee, S.-
dc.contributor.authorLi, F.-
dc.contributor.authorLivan, M.-
dc.contributor.authorMeoni, E.-
dc.contributor.authorScuri, F.-
dc.contributor.authorSill, A.-
dc.contributor.authorWigmans, R.-
dc.date.accessioned2021-09-04T03:13:26Z-
dc.date.available2021-09-04T03:13:26Z-
dc.date.created2021-06-18-
dc.date.issued2016-02-01-
dc.identifier.issn0168-9002-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/89559-
dc.description.abstractThe performance of the RD52 dual-readout calorimeter is measured for very small angles of incidence between the 20 GeV electron beam particles and the direction of the fibers that form the active elements of this calorimeter. The calorimeter response is observed to be independent of the angle of incidence for both the scintillating and the Cerenkov fibers, whereas significant differences are found between the angular dependence of the energy resolution measured with these two types of fibers. The experimental results are on crucial points at variance with the predictions of GEANT4 Monte Carlo simulations. (C) 2015 Elsevier B.V. All rights reserved.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherELSEVIER SCIENCE BV-
dc.subjectELECTRON-
dc.titleThe small-angle performance of a dual-readout fiber calorimeter-
dc.typeArticle-
dc.contributor.affiliatedAuthorChoi, S.-
dc.identifier.doi10.1016/j.nima.2015.11.005-
dc.identifier.scopusid2-s2.0-84948402476-
dc.identifier.wosid000367095600006-
dc.identifier.bibliographicCitationNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, v.808, pp.41 - 53-
dc.relation.isPartOfNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT-
dc.citation.titleNUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT-
dc.citation.volume808-
dc.citation.startPage41-
dc.citation.endPage53-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaInstruments & Instrumentation-
dc.relation.journalResearchAreaNuclear Science & Technology-
dc.relation.journalResearchAreaPhysics-
dc.relation.journalWebOfScienceCategoryInstruments & Instrumentation-
dc.relation.journalWebOfScienceCategoryNuclear Science & Technology-
dc.relation.journalWebOfScienceCategoryPhysics, Nuclear-
dc.relation.journalWebOfScienceCategoryPhysics, Particles & Fields-
dc.subject.keywordPlusELECTRON-
dc.subject.keywordAuthorDual-readout calorimetry-
dc.subject.keywordAuthorCerenkov light-
dc.subject.keywordAuthorOptical fibers-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Science > Department of Physics > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher CHOI, Su yong photo

CHOI, Su yong
이과대학 (물리학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE