Detailed Information

Cited 0 time in webofscience Cited 0 time in scopus
Metadata Downloads

A Novel Fixation Method for Variable-Sized Endoscopic Submucosal Dissection Specimens: An In Vitro Animal Experiment

Full metadata record
DC Field Value Language
dc.contributor.authorKim, Seung Han-
dc.contributor.authorChoi, Hyuk Soon-
dc.contributor.authorChun, Hoon Jai-
dc.contributor.authorYoo, In Kyung-
dc.contributor.authorLee, Jae Min-
dc.contributor.authorKim, Eun Sun-
dc.contributor.authorKeum, Bora-
dc.contributor.authorSeo, Yeon Seok-
dc.contributor.authorJeen, Yoon Tae-
dc.contributor.authorLee, Hong Sik-
dc.contributor.authorUm, Soon Ho-
dc.contributor.authorKim, Chang Duck-
dc.date.accessioned2021-09-04T04:11:03Z-
dc.date.available2021-09-04T04:11:03Z-
dc.date.created2021-06-18-
dc.date.issued2016-01-07-
dc.identifier.issn1932-6203-
dc.identifier.urihttps://scholar.korea.ac.kr/handle/2021.sw.korea/89826-
dc.description.abstractBackground Endoscopic submucosal dissection is considered a curative and minimally invasive treatment for early gastric cancer; however, precise pathologic assessment of resected specimens is required to develop further treatment plans. Human error during specimen handling can affect objective assessment of resected specimens. In this study, we investigated whether a novel tissue fixation device offered more objective and standardized pathologic evaluation than conventional manual tissue fixation. Methods We developed a novel tissue fixation device for endoscopic submucosal dissection specimens. Two circular tissue samples 2, 3, and 4 cm in diameter were obtained from the body of 45 porcine stomachs. One specimen sample was placed in a fixation device; the other was manually fixed on corkboard. We used a pressure indicator to ensure constant pressure in the resected specimens in the fixation device. We measured submucosal diameter and thickness after 24 hr. Results The diameters for 2, 3, and 4 cm resected tissue samples were 23.85, 32.30, and 45.0 mm and 21.0, 32.0, and 44.50 mm for the fixation device and manual pinning groups, respectively. The submucosal thicknesses in the fixation device group were 397.09, 381.43, and 415.51 mu m and 393.76, 529.69, and 603.82 mu m by manual pinning for 2, 3, and 4 cm tissue samples, respectively. Analysis of standard deviation revealed that the submucosal thickness in the manual fixation group was much more variable than in the fixation device group (p = 0.012, 0.042, and 0.001 for 2, 3, and 4 cm tissue specimens, respectively; Fligner-Killeen test of homogeneity of variances). Conclusions Among variously sized resected tissue specimens, submucosal thicknesses were more variable in the conventional fixation group, while the thicknesses were comparatively consistent in the fixation device group. After endoscopic submucosal dissection, pathologic preparation using this fixation device could offer more objective assessment of specimens.-
dc.languageEnglish-
dc.language.isoen-
dc.publisherPUBLIC LIBRARY SCIENCE-
dc.subjectEARLY GASTRIC-CANCER-
dc.subjectLONG-TERM OUTCOMES-
dc.subjectLYMPH-NODE METASTASIS-
dc.subjectMUCOSAL RESECTION-
dc.subjectSINGLE-CENTER-
dc.subjectINVASION-
dc.titleA Novel Fixation Method for Variable-Sized Endoscopic Submucosal Dissection Specimens: An In Vitro Animal Experiment-
dc.typeArticle-
dc.contributor.affiliatedAuthorKim, Seung Han-
dc.contributor.affiliatedAuthorChoi, Hyuk Soon-
dc.contributor.affiliatedAuthorChun, Hoon Jai-
dc.contributor.affiliatedAuthorLee, Jae Min-
dc.contributor.affiliatedAuthorKim, Eun Sun-
dc.contributor.affiliatedAuthorKeum, Bora-
dc.contributor.affiliatedAuthorSeo, Yeon Seok-
dc.contributor.affiliatedAuthorJeen, Yoon Tae-
dc.contributor.affiliatedAuthorLee, Hong Sik-
dc.contributor.affiliatedAuthorUm, Soon Ho-
dc.contributor.affiliatedAuthorKim, Chang Duck-
dc.identifier.doi10.1371/journal.pone.0146573-
dc.identifier.scopusid2-s2.0-84954047076-
dc.identifier.wosid000367810600059-
dc.identifier.bibliographicCitationPLOS ONE, v.11, no.1-
dc.relation.isPartOfPLOS ONE-
dc.citation.titlePLOS ONE-
dc.citation.volume11-
dc.citation.number1-
dc.type.rimsART-
dc.type.docTypeArticle-
dc.description.journalClass1-
dc.description.journalRegisteredClassscie-
dc.description.journalRegisteredClassscopus-
dc.relation.journalResearchAreaScience & Technology - Other Topics-
dc.relation.journalWebOfScienceCategoryMultidisciplinary Sciences-
dc.subject.keywordPlusEARLY GASTRIC-CANCER-
dc.subject.keywordPlusLONG-TERM OUTCOMES-
dc.subject.keywordPlusLYMPH-NODE METASTASIS-
dc.subject.keywordPlusMUCOSAL RESECTION-
dc.subject.keywordPlusSINGLE-CENTER-
dc.subject.keywordPlusINVASION-
Files in This Item
There are no files associated with this item.
Appears in
Collections
College of Medicine > Department of Medical Science > 1. Journal Articles

qrcode

Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.

Related Researcher

Researcher Seo, Yeon Seok photo

Seo, Yeon Seok
의과대학 (의학과)
Read more

Altmetrics

Total Views & Downloads

BROWSE