Design of a Linear Detector Array Unit for High Energy X-ray Helical Computed Tomography and Linear Scanner
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 이정태 | - |
dc.contributor.author | 박종환 | - |
dc.contributor.author | 김현덕 | - |
dc.contributor.author | 김기윤 | - |
dc.contributor.author | 김동근 | - |
dc.contributor.author | 박신웅 | - |
dc.contributor.author | 이윤 | - |
dc.contributor.author | 조규성 | - |
dc.date.accessioned | 2021-09-04T06:12:14Z | - |
dc.date.available | 2021-09-04T06:12:14Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2016 | - |
dc.identifier.issn | 1976-2402 | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/90688 | - |
dc.description.abstract | A linear detector array unit (LDAU) was proposed and designed for the high energy X-ray 2-D and 3-D imaging systems for industrial non-destructive test. Specially for 3-D imaging, a helical CT with a 15 MeV linear accelerator and a curved detector is proposed. The arc-shape detector can be formed by many LDAUs all of which are arranged to face the focal spot when the source-to-detector distance is fixed depending on the application. An LDAU is composed of 10 modules and each module has 48 channels of CdWO4 (CWO) blocks and Si PIN photodiodes with 0.4 mm pitch. This modular design was made for easy manufacturing and maintenance. Through the Monte Carlo simulation, the CWO detector thickness of 17 mm was optimally determined. The silicon PIN photodiodes were designed as 48 channel arrays and fabricated with NTD (neutron transmutation doping) wafers of high resistivity and showed excellent leakage current properties below 1 nA at 10 V reverse bias. To minimize the low-voltage breakdown, the edges of the active layer and the guard ring were designed as a curved shape. The data acquisition system was also designed and fabricated as three independent functional boards; a sensor board, a capture board and a communication board to a PC. This paper describes the design of the detectors (CWO blocks and Si PIN photodiodes) and the 3-board data acquisition system with their simulation results. | - |
dc.language | English | - |
dc.language.iso | en | - |
dc.publisher | (사)한국방사선산업학회 | - |
dc.title | Design of a Linear Detector Array Unit for High Energy X-ray Helical Computed Tomography and Linear Scanner | - |
dc.title.alternative | Design of a Linear Detector Array Unit for High Energy X-ray Helical Computed Tomography and Linear Scanner | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 박신웅 | - |
dc.contributor.affiliatedAuthor | 이윤 | - |
dc.identifier.bibliographicCitation | 방사선산업학회지, v.10, no.3, pp.145 - 152 | - |
dc.relation.isPartOf | 방사선산업학회지 | - |
dc.citation.title | 방사선산업학회지 | - |
dc.citation.volume | 10 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 145 | - |
dc.citation.endPage | 152 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002155617 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.description.journalRegisteredClass | other | - |
dc.subject.keywordAuthor | High energy X-ray | - |
dc.subject.keywordAuthor | Helical CT | - |
dc.subject.keywordAuthor | Non-destructive test (NDT) | - |
dc.subject.keywordAuthor | Linear accelerator (LINAC) | - |
dc.subject.keywordAuthor | Linear detector array unit (LDAU) | - |
dc.subject.keywordAuthor | CWO | - |
dc.subject.keywordAuthor | Si PIN photodiode | - |
dc.subject.keywordAuthor | Data acquisition system (DAS) | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.