고층 RC 벽식 건물의 지진 취약도 분석
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 정기현 | - |
dc.contributor.author | 이한선 | - |
dc.contributor.author | 황경란 | - |
dc.contributor.author | 권오성 | - |
dc.contributor.author | 김승직 | - |
dc.date.accessioned | 2021-09-04T07:04:49Z | - |
dc.date.available | 2021-09-04T07:04:49Z | - |
dc.date.created | 2021-06-17 | - |
dc.date.issued | 2016 | - |
dc.identifier.issn | 1226-525X | - |
dc.identifier.uri | https://scholar.korea.ac.kr/handle/2021.sw.korea/90926 | - |
dc.description.abstract | Observations of the damages to high-rise reinforced concrete (RC) wall building structures caused by by recent earthquakes in Chile (Mw 8.8, February 2010) and New Zealand (February 2011, ML 6.3) have generally exceeded expectations. Firstly, this study estimated the seismic damage levels of 15-story RC box-type wall building structures using the analytical models calibrated by the results of a shaking table test on a 1:5 scale 10-story RC box-type wall building model. Then, the seismic fragility analysis of the prototype model was conducted by using the SAC/FEMA method and the incremental dynamic analysis (IDA). To compensate for the uncertainties and variability of ground motion and its impacts on the prototype model, in the SAC/FEMA method, a total of 61 ground motion records were selected from 20 earthquakes, with a magnitude ranging from 5.9 to 8.8 and an epicentral distance ranging from 5 to 105km. In the IDA, a total of 11 ground motion records were used based on the uniform hazard response spectrum representing a return period of 2,475 years. As a result, the probabilities that the limits of the serviceability, damage control, and collapse prevention would be exceeded were as follows: from the SAC/FEMA method: 79%, 0.3%, and 0%, respectively; and from the IDA: 57%, 1.7%, and 0%, respectively. | - |
dc.language | Korean | - |
dc.language.iso | ko | - |
dc.publisher | 한국지진공학회 | - |
dc.title | 고층 RC 벽식 건물의 지진 취약도 분석 | - |
dc.title.alternative | Seismic Fragility Analysis of High-Rise RC Box-Type Wall Building Structures | - |
dc.type | Article | - |
dc.contributor.affiliatedAuthor | 이한선 | - |
dc.identifier.bibliographicCitation | 한국지진공학회논문집, v.20, no.3, pp.155 - 162 | - |
dc.relation.isPartOf | 한국지진공학회논문집 | - |
dc.citation.title | 한국지진공학회논문집 | - |
dc.citation.volume | 20 | - |
dc.citation.number | 3 | - |
dc.citation.startPage | 155 | - |
dc.citation.endPage | 162 | - |
dc.type.rims | ART | - |
dc.identifier.kciid | ART002103892 | - |
dc.description.journalClass | 2 | - |
dc.description.journalRegisteredClass | kci | - |
dc.subject.keywordAuthor | Seismic fragility | - |
dc.subject.keywordAuthor | time history analysis | - |
dc.subject.keywordAuthor | RC wall | - |
dc.subject.keywordAuthor | Incremental dynamic analysis | - |
Items in ScholarWorks are protected by copyright, with all rights reserved, unless otherwise indicated.
(02841) 서울특별시 성북구 안암로 14502-3290-1114
COPYRIGHT © 2021 Korea University. All Rights Reserved.
Certain data included herein are derived from the © Web of Science of Clarivate Analytics. All rights reserved.
You may not copy or re-distribute this material in whole or in part without the prior written consent of Clarivate Analytics.